. 2015 May;22(10):7716-25.
doi: 10.1007/s11356-014-4011-4. Epub 2015 Jan 6.

Amine-functionalized mesoporous polymer as potential sorbent for nickel preconcentration from electroplating wastewater

Affiliations

Amine-functionalized mesoporous polymer as potential sorbent for nickel preconcentration from electroplating wastewater

Aminul Islam et al. Environ Sci Pollut Res Int. 2015 May.

Abstract

In this study, mesoporous glycidyl methacrylate-divinylbenzene-based chelating resin was synthesized and grafted with diethylenetriamine through epoxy ring-opening reaction. The synthesized resin was characterized by elemental analysis, infrared spectroscopy, surface area and pore size analysis, scanning electron microscopy, energy-dispersive spectroscopy, and thermogravimetry. The resin was used for the first time as an effective sorbent for the preconcentration of nickel in electroplating wastewater samples. The analytical variables like pH, flow rate for sorption/desorption, and eluate selection were systematically investigated and optimized. The uniform and monolayer sorption behavior of resin for nickel was proved by an evident fit of the equilibrium data to a Langmuir isotherm model. Under optimized conditions, the resin was observed to show a good sorption capacity of 20.25 mg g(-1) and >96% recovery of nickel even in the presence of a large number of competitive matrix ions. Its ability to extract trace amount of nickel was exhibited by low preconcentration limit (5.9 μg L(-1)). The calibration curve was found to be linear (R(2) = 0.998) in the concentration range of 6.0-400.0 μg L(-1). Coefficient of variation of less than 5 for all the analysis indicated good reproducibility. The reliability was evaluated by the analysis of standard reference material (SRM) and recovery experiments. The applicability of the resin for the systematic preconcentration of nickel is substantiated by the analysis of electroplating wastewater and river water samples. Graphical abstract ᅟ.

PubMed Disclaimer

Similar articles

References

    1. Environ Monit Assess. 2011 Apr;175(1-4):201-12 - PubMed
    1. J Chromatogr A. 2014 May 23;1343:128-34 - PubMed
    1. Environ Sci Pollut Res Int. 2014 Oct;21(20):12017-27 - PubMed
    1. Environ Sci Pollut Res Int. 2011 Nov;18(9):1633-43 - PubMed
    1. Environ Monit Assess. 2013 Mar;185(3):2691-704 - PubMed

Publication types

LinkOut - more resources