Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Mar;65(2):143-6.
doi: 10.1093/occmed/kqu189. Epub 2015 Jan 7.

Validation of the firefighter WFI treadmill protocol for predicting VO2 max

Affiliations

Validation of the firefighter WFI treadmill protocol for predicting VO2 max

B A Dolezal et al. Occup Med (Lond). 2015 Mar.

Abstract

Background: The Wellness-Fitness Initiative submaximal treadmill exercise test (WFI-TM) is recommended by the US National Fire Protection Agency to assess aerobic capacity (VO2 max) in firefighters. However, predicting VO2 max from submaximal tests can result in errors leading to erroneous conclusions about fitness.

Aims: To investigate the level of agreement between VO2 max predicted from the WFI-TM against its direct measurement using exhaled gas analysis.

Methods: The WFI-TM was performed to volitional fatigue. Differences between estimated VO2 max (derived from the WFI-TM equation) and direct measurement (exhaled gas analysis) were compared by paired t-test and agreement was determined using Pearson Product-Moment correlation and Bland-Altman analysis. Statistical significance was set at P < 0.05.

Results: Fifty-nine men performed the WFI-TM. Mean (standard deviation) values for estimated and measured VO2 max were 44.6 (3.4) and 43.6 (7.9) ml/kg/min, respectively (P < 0.01). The mean bias by which WFI-TM overestimated VO2 max was 0.9ml/kg/min with a 95% prediction interval of ±13.1. Prediction errors for 22% of subjects were within ±5%; 36% had errors greater than or equal to ±15% and 7% had greater than ±30% errors. The correlation between predicted and measured VO2 max was r = 0.55 (standard error of the estimate = 2.8ml/kg/min).

Conclusions: WFI-TM predicts VO2 max with 11% error. There is a tendency to overestimate aerobic capacity in less fit individuals and to underestimate it in more fit individuals leading to a clustering of values around 42ml/kg/min, a criterion used by some fire departments to assess fitness for duty.

Keywords: Firefighters; fitness tests; physical fitness..

PubMed Disclaimer

Similar articles

Cited by

Publication types