Abstract
Previous studies have found inconsistent results from testing methods used to measure heterotrophic plate count (HPC) bacteria in dental unit waterline (DUWL) samples. This study used 63 samples to compare the results obtained from an in-office chairside method and 2 currently used commercial laboratory HPC methods (Standard Methods 9215C and 9215E). The results suggest that the Standard Method 9215E is not suitable for application to DUWL quality monitoring, due to the detection of limited numbers of heterotrophic organisms at the required 35°C incubation temperature. The results also confirm that while the in-office chairside method is useful for DUWL quality monitoring, the Standard Method 9215C provided the most accurate results.
Figures

Similar articles
-
Evaluation of in-office dental unit waterline testing.Gen Dent. 2012 May-Jun;60(3):e142-7. Gen Dent. 2012. PMID: 22623469
-
Formation and decontamination of biofilms in dental unit waterlines.J Periodontol. 2003 Nov;74(11):1595-609. doi: 10.1902/jop.2003.74.11.1595. J Periodontol. 2003. PMID: 14682656
-
Dental Unit Waterlines in Quito and Caracas Contaminated with Nontuberculous Mycobacteria: A Potential Health Risk in Dental Practice.Int J Environ Res Public Health. 2020 Mar 31;17(7):2348. doi: 10.3390/ijerph17072348. Int J Environ Res Public Health. 2020. PMID: 32244267 Free PMC article.
-
Microbial contamination of dental unit waterlines.Ann Agric Environ Med. 2008;15(2):173-9. Ann Agric Environ Med. 2008. PMID: 19061251 Review.
-
Management of dental unit waterline biofilms in the 21st century.Future Microbiol. 2011 Oct;6(10):1209-26. doi: 10.2217/fmb.11.104. Future Microbiol. 2011. PMID: 22004039 Review.
Cited by
-
Three key factors influencing the bacterial contamination of dental unit waterlines: a 6-year survey from 2012 to 2017.Int Dent J. 2019 Jun;69(3):192-199. doi: 10.1111/idj.12456. Epub 2018 Dec 19. Int Dent J. 2019. PMID: 30565215 Free PMC article.
-
Evaluation of bacterial contamination of dental unit waterlines and use of a newly designed measurement device to assess retraction of a dental chair unit.Int Dent J. 2016 Aug;66(4):208-14. doi: 10.1111/idj.12225. Epub 2016 Mar 21. Int Dent J. 2016. PMID: 27000421 Free PMC article.
-
Water Contamination Risks at the Dental Clinic.Biology (Basel). 2020 Feb 27;9(3):43. doi: 10.3390/biology9030043. Biology (Basel). 2020. PMID: 32120909 Free PMC article.
References
-
- Mills SE. The dental unit waterline controversy: defusing the myths, defining the solutions. J Am Dent Assoc. 2000;131(10):1427–1441. - PubMed
-
- Szymanska J. Bacterial contamination of water in dental unit reservoirs. Ann Agric Environ Med. 2007;14(1):137–140. - PubMed
-
- Cunningham AB, Lennox JE, Ross RJ, editors. [Accessed November 7, 2014];Biofilm growth and development. Biofilms: The Hypertextbook. Available at: http://www.biofilmbook.com.
-
- Kohn WG, Collins AS, Cleveland JL, et al. Guidelines for infection control in dental health-care settings – 2003. MMWR Recomm Rep. 2003;52(RR17):1–61. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources