A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses
- PMID: 25574755
- DOI: 10.1088/0031-9155/60/3/N21
A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses
Abstract
This work presents the first study of x-ray phase contrast imaging based on a simple implementation of the edge illumination method (EIXPCi) in the field of mammography with synchrotron radiation. A simplified EIXPCi set-up was utilized to study a possible application in mammography at clinical doses. Moreover, through a novel algorithm capable of separating and quantifying absorption and phase perturbations of images acquired in EIXPCi modality, it is possible to extract quantitative information on breast images, allowing an accurate tissue identification. The study was carried out at the SYRMEP beamline of Elettra synchrotron radiation facility (Trieste, Italy), where a mastectomy specimen was investigated with the EIXPCi technique. The sample was exposed at three different energies suitable for mammography with synchrotron radiation in order to test the validity of the novel algorithm in extracting values of linear attenuation coefficients integrated over the sample thickness. It is demonstrated that the quantitative data are in good agreement with the theoretical values of linear attenuation coefficients calculated on the hypothesis of the breast with a given composition. The results are promising and encourage the current efforts to apply the method in mammography with synchrotron radiation.
Similar articles
-
Breast tomography with synchrotron radiation: preliminary results.Phys Med Biol. 2004 May 7;49(9):1739-54. doi: 10.1088/0031-9155/49/9/011. Phys Med Biol. 2004. PMID: 15152928
-
Monte Carlo simulation of breast imaging using synchrotron radiation.Med Phys. 2012 Apr;39(4):2069-77. doi: 10.1118/1.3694670. Med Phys. 2012. PMID: 22482628
-
A method for high-energy, low-dose mammography using edge illumination x-ray phase-contrast imaging.Phys Med Biol. 2016 Dec 21;61(24):8750-8761. doi: 10.1088/1361-6560/61/24/8750. Epub 2016 Nov 28. Phys Med Biol. 2016. PMID: 27893445
-
[X-ray phase imaging using a X-ray tube with a small focal spot -improvement of image quality in mammography-].Igaku Butsuri. 2002;22(1):21-9. Igaku Butsuri. 2002. PMID: 12766293 Review. Japanese.
-
Medical applications of synchrotron radiation.Phys Med Biol. 2003 Jul 7;48(13):R1-35. doi: 10.1088/0031-9155/48/13/201. Phys Med Biol. 2003. PMID: 12884920 Review.
Cited by
-
Dose and diagnostic performance comparison between phase-contrast mammography with synchrotron radiation and digital mammography: a clinical study report.J Med Imaging (Bellingham). 2018 Jan;5(1):013503. doi: 10.1117/1.JMI.5.1.013503. Epub 2018 Feb 1. J Med Imaging (Bellingham). 2018. PMID: 29430473 Free PMC article.
-
Recent advances in edge illumination x-ray phase-contrast tomography.J Med Imaging (Bellingham). 2017 Oct;4(4):040901. doi: 10.1117/1.JMI.4.4.040901. Epub 2017 Oct 16. J Med Imaging (Bellingham). 2017. PMID: 29057286 Free PMC article. Review.
-
Edge-illumination x-ray phase-contrast imaging.J Phys Condens Matter. 2021 Jul 13;33(36):363002. doi: 10.1088/1361-648X/ac0e6e. J Phys Condens Matter. 2021. PMID: 34167096 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical