Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Mar;25(3):947-55.
doi: 10.1007/s00586-015-3758-8. Epub 2015 Jan 10.

Robot-assisted spine surgery: feasibility study through a prospective case-matched analysis

Affiliations

Robot-assisted spine surgery: feasibility study through a prospective case-matched analysis

Nicolas Lonjon et al. Eur Spine J. 2016 Mar.

Abstract

Purpose: While image guidance and neuronavigation have enabled a more accurate placement of pedicle implants, they can inconvenience the surgeon. Robot-assisted placement of pedicle screws appears to overcome these disadvantages. However, recent data concerning the superiority of currently available robots in assisting spinal surgeons are conflicting. The aim of our study was to evaluate the percentage of accurately placed pedicle screws, inserted using a new robotic-guidance system.

Method: 20 Patients were operated on successively by the same surgeon using robotic assistance (ROSA™, Medtech) (Rosa group 10 patients, n = 40 screws) or by the freehand conventional technique (Freehand group 10 patients, n = 50 screws). Patient characteristics as well as the duration of the operation and of exposure to X rays were recorded.

Results: The mean age of patients in each group (RG and FHG) was 63 years. Mean BMI and operating time among the RG and FHG were, respectively, 26 and 27 kg/m(2), and 187 and 119 min. Accurate placement of the implant (score A and B of the Gertzbein Robbins classification) was achieved in 97.3% of patients in the RG (n = 36) and in 92% of those in the FHG (n = 50). Four implants in the RG were placed manually following failed robotic assistance.

Conclusion: We report a higher rate of precision with robotic as compared to the FH technique. Providing assistance by permanently monitoring the patient's movements, this image-guided tool helps more accurately pinpoint the pedicle entry point and control the trajectory. Limitations of the study include its small sized and non-randomized sample. Nevertheless, these preliminary results are encouraging for the development of new robotic techniques for spinal surgery.

Keywords: Degenerative disease; Lumbar; Robot-assisted; Spine surgery.

PubMed Disclaimer

References

    1. Acta Neurochir (Wien). 2011 Mar;153(3):589-96 - PubMed
    1. Spine (Phila Pa 1976). 2000 Jun 15;25(12 ):1538-41 - PubMed
    1. Neurosurgery. 2001 Apr;48(4):771-8; discussion 778-9 - PubMed
    1. Spine (Phila Pa 1976). 2010 Nov 15;35(24):2109-15 - PubMed
    1. J Spinal Disord Tech. 2009 Oct;22(7):468-72 - PubMed

LinkOut - more resources