Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Feb;9(1):39-43.
doi: 10.1007/s11832-015-0631-6. Epub 2015 Jan 15.

Local and systemic metal ion release occurs intraoperatively during correction and instrumented spinal fusion for scoliosis

Affiliations

Local and systemic metal ion release occurs intraoperatively during correction and instrumented spinal fusion for scoliosis

William J Cundy et al. J Child Orthop. 2015 Feb.

Abstract

Study design: Prospective pilot study.

Objectives: The aim of this study was to measure titanium, niobium and aluminium levels in various intraoperative and postoperative samples to determine patterns of metal ion release that occur within the first month following instrumented spinal fusion. Raised serum metal ion levels are reported following instrumented spinal fusion in adolescent idiopathic scoliosis. The exact topological origin and chronology of metal ion release remains conjectural. Recent literature suggests an immediate rise in serum metal levels within the first postoperative week.

Methods: Titanium, niobium and aluminium levels were measured before, during and after surgery in serum and local intraoperative fluid samples obtained from two pediatric patients undergoing posterior correction and instrumentation for scoliosis.

Results: Measurable metal ion levels were detected in all local samples obtained from wound irrigation fluid, cell saver blood, and fluid that immersed metal universal reduction screw tabs. Postoperative serum metal ion levels were elevated compared to baseline preoperative levels. In general, metal ion levels were considerably higher in the intraoperative fluid samples compared to those observed in the serum levels.

Conclusion: Our findings of contextually high metal ion concentrations in intraoperative and early postoperative samples provide further empirical support of a 'putting-in' phenomenon of metal ion release following instrumented spinal fusion. This challenges existing beliefs that metal ion release occurs during an intermediate 'wearing-in' phase. We recommend thorough irrigation of the operative site prior to wound closure to dilute and remove intraoperative metal ion debris. Possibilities of filtering trace metal ions from cell saver content may be considered.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Titanium, niobium and aluminium levels from local and systemic fluid samples taken at various time intervals (Fig. 1a, b, c, respectively). Cell saver and wound irrigation data labels represent mean values (n = 2)

References

    1. Cundy TP, Antoniou G, Sutherland LM, Freeman BJ, Cundy PJ. Serum titanium, niobium, and aluminum levels after instrumented spinal arthrodesis in children. Spine. 2013;38(7):564–570. doi: 10.1097/BRS.0b013e3182741961. - DOI - PubMed
    1. Rackham MD, Cundy TP, Antoniou G, Freeman BJ, Sutherland LM, Cundy PJ. Predictors of serum chromium levels after stainless steel posterior spinal instrumentation for adolescent idiopathic scoliosis. Spine. 2010;35(9):975–982. doi: 10.1097/BRS.0b013e3181d7a197. - DOI - PubMed
    1. Cundy TP, Delaney CL, Rackham MD, Antoniou G, Oakley AP, Freeman BJ, Sutherland LM, Cundy PJ. Chromium ion release from stainless steel pediatric scoliosis instrumentation. Spine. 2010;35(9):967–974. doi: 10.1097/BRS.0b013e3181d53724. - DOI - PubMed
    1. Richardson TD, Pineda SJ, Strenge KB, Van Fleet TA, MacGregor M, Milbrandt JC, Espinosa JA, Freitag P. Serum titanium levels after instrumented spinal arthrodesis. Spine. 2008;33(7):792–796. doi: 10.1097/BRS.0b013e318169574d. - DOI - PubMed
    1. Mueller FJ, Gluch H. Adolescent idiopathic scoliosis (AIS) treated with arthrodesis and posterior titanium instrumentation: 8–12 years follow up without late infection. Scoliosis. 2009;4:16. doi: 10.1186/1748-7161-4-16. - DOI - PMC - PubMed

LinkOut - more resources