Relative flow reserve derived from quantitative perfusion imaging may not outperform stress myocardial blood flow for identification of hemodynamically significant coronary artery disease
- PMID: 25596142
- DOI: 10.1161/CIRCIMAGING.114.002400
Relative flow reserve derived from quantitative perfusion imaging may not outperform stress myocardial blood flow for identification of hemodynamically significant coronary artery disease
Abstract
Background: Quantitative myocardial perfusion imaging is increasingly used for the diagnosis of coronary artery disease. Quantitative perfusion imaging allows to noninvasively calculate fractional flow reserve (FFR). This so-called relative flow reserve (RFR) is defined as the ratio of hyperemic myocardial blood flow (MBF) in a stenotic area to hyperemic MBF in a normal perfused area. The aim of this study was to assess the value of RFR in the detection of significant coronary artery disease.
Methods and results: From a clinical population of patients with suspected coronary artery disease who underwent oxygen-15-labeled water cardiac positron emission tomography and invasive coronary angiography, 92 patients with single- or 2-vessel disease were included. Intermediate lesions (diameter stenosis, 30%-90%; n=75) were interrogated by FFR. Thirty-eight (41%) vessels were deemed hemodynamically significant (>90% stenosis or FFR≤0.80). Hyperemic MBF, coronary flow reserve, and RFR were lower for vessels with a hemodynamically significant lesion (2.01±0.78 versus 2.90±1.16 mL·min(-1)·g(-1); P<0.001, 2.27±1.03 versus 3.10±1.29; P<0.001, and 0.67±0.23 versus 0.93±0.15; P<0.001, respectively). The correlation between RFR and FFR was moderate (r=0.54; P<0.01). Receiver operator characteristic curve analysis showed an area under the curve of 0.82 for RFR, which was not significantly higher compared with that for hyperemic MBF and coronary flow reserve (0.76; P=0.32 and 0.72; P=0.08, respectively).
Conclusions: Noninvasive estimation of FFR by quantitative perfusion positron emission tomography by calculating RFR is feasible, yet only a trend toward a slight improvement of diagnostic accuracy compared with hyperemic MBF assessment was determined.
Keywords: coronary angiography; coronary artery disease; fractional flow reserve, myocardial; positron-emission tomography.
© 2015 American Heart Association, Inc.
Comment in
-
Physiologic stenosis severity, binary thinking, revascularization, and "hidden reality".Circ Cardiovasc Imaging. 2015 Jan;8(1):e002970. doi: 10.1161/CIRCIMAGING.114.002970. Circ Cardiovasc Imaging. 2015. PMID: 25596144 No abstract available.
Similar articles
-
Integrated Myocardial Perfusion Imaging Diagnostics Improve Detection of Functionally Significant Coronary Artery Stenosis by 13N-ammonia Positron Emission Tomography.Circ Cardiovasc Imaging. 2016 Sep;9(9):e004768. doi: 10.1161/CIRCIMAGING.116.004768. Circ Cardiovasc Imaging. 2016. PMID: 27609817
-
Diagnostic accuracy of stress myocardial perfusion imaging compared to invasive coronary angiography with fractional flow reserve meta-analysis.Circ Cardiovasc Imaging. 2015 Jan;8(1):e002666. doi: 10.1161/CIRCIMAGING.114.002666. Circ Cardiovasc Imaging. 2015. PMID: 25596143 Review.
-
Combined CT coronary angiography and stress myocardial perfusion imaging for hemodynamically significant stenoses in patients with suspected coronary artery disease: a comparison with fractional flow reserve.JACC Cardiovasc Imaging. 2012 Nov;5(11):1097-111. doi: 10.1016/j.jcmg.2012.09.004. JACC Cardiovasc Imaging. 2012. PMID: 23153909
-
Quantitative assessment of myocardial perfusion in the detection of significant coronary artery disease: cutoff values and diagnostic accuracy of quantitative [(15)O]H2O PET imaging.J Am Coll Cardiol. 2014 Oct 7;64(14):1464-75. doi: 10.1016/j.jacc.2014.05.069. J Am Coll Cardiol. 2014. PMID: 25277618
-
Instantaneous wave-free ratio as an alternative to fractional flow reserve in assessment of moderate coronary stenoses: A meta-analysis of diagnostic accuracy studies.Cardiovasc Revasc Med. 2018 Jul-Aug;19(5 Pt B):613-620. doi: 10.1016/j.carrev.2017.12.014. Epub 2017 Dec 27. Cardiovasc Revasc Med. 2018. PMID: 29371084 Review.
Cited by
-
Diagnostic analysis of new quantitative parameters of low-dose dynamic myocardial perfusion imaging with CZT SPECT in the detection of suspected or known coronary artery disease.Int J Cardiovasc Imaging. 2021 Jan;37(1):367-378. doi: 10.1007/s10554-020-01962-x. Epub 2020 Sep 10. Int J Cardiovasc Imaging. 2021. PMID: 32914404 Free PMC article.
-
Dynamic cardiac PET motion correction using 3D normalized gradient fields in patients and phantom simulations.Med Phys. 2021 Sep;48(9):5072-5084. doi: 10.1002/mp.15059. Epub 2021 Jul 20. Med Phys. 2021. PMID: 34174095 Free PMC article.
-
Myocardial perfusion imaging by 15O-H2O positron emission tomography predicts clinical revascularization procedures in symptomatic patients with previous coronary artery bypass graft.Eur Heart J Open. 2023 Apr 28;3(3):oead044. doi: 10.1093/ehjopen/oead044. eCollection 2023 May. Eur Heart J Open. 2023. PMID: 37206919 Free PMC article.
-
Quantitative Myocardial Perfusion in Surgically Repaired Coronary Artery Anomaly.Ann Thorac Surg Short Rep. 2022 Jul 16;1(1):30-33. doi: 10.1016/j.atssr.2022.06.003. eCollection 2023 Mar. Ann Thorac Surg Short Rep. 2022. PMID: 39790501 Free PMC article.
-
Correlation of FFR-derived from CT and stress perfusion CMR with invasive FFR in intermediate-grade coronary artery stenosis.Int J Cardiovasc Imaging. 2019 Mar;35(3):559-568. doi: 10.1007/s10554-018-1464-4. Epub 2018 Oct 3. Int J Cardiovasc Imaging. 2019. PMID: 30284138
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous