Image quality and radiation reduction of 320-row area detector CT coronary angiography with optimal tube voltage selection and an automatic exposure control system: comparison with body mass index-adapted protocol
- PMID: 25604967
- DOI: 10.1007/s10554-015-0594-1
Image quality and radiation reduction of 320-row area detector CT coronary angiography with optimal tube voltage selection and an automatic exposure control system: comparison with body mass index-adapted protocol
Abstract
To assess the image quality and radiation exposure of 320-row area detector computed tomography (320-ADCT) coronary angiography with optimal tube voltage selection with the guidance of an automatic exposure control system in comparison with a body mass index (BMI)-adapted protocol. Twenty-two patients (study group) underwent 320-ADCT coronary angiography using an automatic exposure control system with the target standard deviation value of 33 as the image quality index and the lowest possible tube voltage. For comparison, a sex- and BMI-matched group (control group, n = 22) using a BMI-adapted protocol was established. Images of both groups were reconstructed by an iterative reconstruction algorithm. For objective evaluation of the image quality, image noise, vessel density, signal to noise ratio (SNR), and contrast to noise ratio (CNR) were measured. Two blinded readers then subjectively graded the image quality using a four-point scale (1: nondiagnostic to 4: excellent). Radiation exposure was also measured. Although the study group tended to show higher image noise (14.1 ± 3.6 vs. 9.3 ± 2.2 HU, P = 0.111) and higher vessel density (665.5 ± 161 vs. 498 ± 143 HU, P = 0.430) than the control group, the differences were not significant. There was no significant difference between the two groups for SNR (52.5 ± 19.2 vs. 60.6 ± 21.8, P = 0.729), CNR (57.0 ± 19.8 vs. 67.8 ± 23.3, P = 0.531), or subjective image quality scores (3.47 ± 0.55 vs. 3.59 ± 0.56, P = 0.960). However, radiation exposure was significantly reduced by 42 % in the study group (1.9 ± 0.8 vs. 3.6 ± 0.4 mSv, P = 0.003). Optimal tube voltage selection with the guidance of an automatic exposure control system in 320-ADCT coronary angiography allows substantial radiation reduction without significant impairment of image quality, compared to the results obtained using a BMI-based protocol.
Similar articles
-
Improved image quality with simultaneously reduced radiation exposure: Knowledge-based iterative model reconstruction algorithms for coronary CT angiography in a clinical setting.J Cardiovasc Comput Tomogr. 2017 May-Jun;11(3):213-220. doi: 10.1016/j.jcct.2017.02.007. Epub 2017 Feb 23. J Cardiovasc Comput Tomogr. 2017. PMID: 28314613 Clinical Trial.
-
Image quality of adaptive iterative dose reduction 3D of coronary CT angiography of 640-slice CT: comparison with filtered back-projection.Int J Cardiovasc Imaging. 2013 Mar;29(3):669-76. doi: 10.1007/s10554-012-0113-6. Epub 2012 Aug 26. Int J Cardiovasc Imaging. 2013. PMID: 22923280
-
Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative reconstruction.Eur J Radiol. 2012 Nov;81(11):3568-76. doi: 10.1016/j.ejrad.2011.06.055. Epub 2011 Jul 23. Eur J Radiol. 2012. PMID: 21784592
-
Acquisition and Reconstruction Techniques for Coronary CT Angiography: Current Status and Trends over the Past Decade.Radiographics. 2025 Jul;45(7):e240083. doi: 10.1148/rg.240083. Radiographics. 2025. PMID: 40504731 Review.
-
Coronary artery vasculitis: assessment with cardiac multi-detector computed tomography.Int J Cardiovasc Imaging. 2015 Jun;31 Suppl 1:59-67. doi: 10.1007/s10554-015-0652-8. Epub 2015 Apr 5. Int J Cardiovasc Imaging. 2015. PMID: 25841665 Review.
Cited by
-
Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy.Eur Radiol. 2016 Nov;26(11):3802-3810. doi: 10.1007/s00330-016-4275-9. Epub 2016 Feb 23. Eur Radiol. 2016. PMID: 26905865
-
Comparison of Iohexol-380 and Iohexol-350 for Coronary CT Angiography: A Multicenter, Randomized, Double-Blind Phase 3 Trial.Korean J Radiol. 2016 May-Jun;17(3):330-8. doi: 10.3348/kjr.2016.17.3.330. Epub 2016 Apr 14. Korean J Radiol. 2016. PMID: 27134522 Free PMC article. Clinical Trial.
-
Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease.Pediatr Cardiol. 2016 Mar;37(3):497-503. doi: 10.1007/s00246-015-1305-3. Epub 2015 Nov 12. Pediatr Cardiol. 2016. PMID: 26563276
-
Quantitative and qualitative assessment of ultra-low-dose paranasal sinus CT using deep learning image reconstruction: a comparison with hybrid iterative reconstruction.Eur Radiol. 2025 Jun 13. doi: 10.1007/s00330-025-11763-2. Online ahead of print. Eur Radiol. 2025. PMID: 40514598
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical