The clinical implications of poly implant prothèse breast implants: an overview
- PMID: 25606483
- PMCID: PMC4297804
- DOI: 10.5999/aps.2015.42.1.4
The clinical implications of poly implant prothèse breast implants: an overview
Abstract
Mammary implants marketed by Poly Implant Prothèse (PIP) were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Prothèse", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635) for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage.
Keywords: Breast implantation; Breast implants; Prosthesis failure; Silicone; Silicone gels.
Conflict of interest statement
No potential conflict of interest relevant to this article was reported.
Figures

Similar articles
-
Complications of Poly Implant Prothèse breast implants: the current discussion.Expert Rev Med Devices. 2013 Mar;10(2):167-70. doi: 10.1586/erd.12.87. Expert Rev Med Devices. 2013. PMID: 23480085
-
Poly Implant Prothèse and Rofil Substandard Breast Implant Explantations from a Large German Single Centre from 2011 to 2014: A Comparative Study.Aesthetic Plast Surg. 2016 Aug;40(4):507-13. doi: 10.1007/s00266-016-0666-1. Epub 2016 Jun 10. Aesthetic Plast Surg. 2016. PMID: 27286854
-
Sentinel lymph node biopsy in a patient with ruptured poly implant prothese (PIP) implants: A case report.Int J Surg Case Rep. 2014;5(12):992-4. doi: 10.1016/j.ijscr.2014.09.005. Epub 2014 Oct 5. Int J Surg Case Rep. 2014. PMID: 25460455 Free PMC article.
-
Silicone lymphadenopathy after breast augmentation: case reports, review of the literature, and current thoughts.Aesthetic Plast Surg. 2013 Apr;37(2):278-89. doi: 10.1007/s00266-012-0025-9. Epub 2013 Jan 26. Aesthetic Plast Surg. 2013. PMID: 23354761 Review.
-
Complication of Ruptured Poly Implant Prothèse® Breast Implants Combined with AQUAfilling® Gel Injection: A Case Report and Literature Review.Aesthetic Plast Surg. 2019 Feb;43(1):46-52. doi: 10.1007/s00266-018-1242-7. Epub 2018 Oct 4. Aesthetic Plast Surg. 2019. PMID: 30288565 Review.
Cited by
-
Medical device regulation (MDR) in health technology enterprises - perspectives of managers and regulatory professionals.BMC Health Serv Res. 2023 Mar 30;23(1):310. doi: 10.1186/s12913-023-09316-8. BMC Health Serv Res. 2023. PMID: 36997978 Free PMC article.
-
Comparative Study Between Breast Implants and Adipose Tissue Autograft in Primary Aesthetic Breast Augmentation.Aesthetic Plast Surg. 2025 Jun 2. doi: 10.1007/s00266-025-04922-9. Online ahead of print. Aesthetic Plast Surg. 2025. PMID: 40456993
-
Squamous Cell Carcinoma as a Result of Likely Industrial Grade Ruptured Poly Implant Prosthèse Silicone Buttock Implants.Aesthet Surg J Open Forum. 2020 Jul 6;2(3):ojaa030. doi: 10.1093/asjof/ojaa030. eCollection 2020 Sep. Aesthet Surg J Open Forum. 2020. PMID: 33791653 Free PMC article.
-
Progressive silicone lymphadenopathy post mastectomy and implant reconstruction for breast cancer.BMJ Case Rep. 2021 Feb 9;14(2):e237711. doi: 10.1136/bcr-2020-237711. BMJ Case Rep. 2021. PMID: 33563690 Free PMC article.
-
Interstitial lung diseases associated with metal content in silicone breast implants: a case series.Sarcoidosis Vasc Diffuse Lung Dis. 2018;35(4):381-389. doi: 10.36141/svdld.v35i4.7029. Epub 2020 Mar 9. Sarcoidosis Vasc Diffuse Lung Dis. 2018. PMID: 32476927 Free PMC article.
References
-
- NHS Choices. PIP breast implants-latest from the NHS [Internet] London: NHS Choices; 2012. [cited 2014 May 16]. Available from: http://www.nhs.uk/news/2012/01January/Pages/government-review-advises-on....
-
- SCENIHR (Scientific Committee on Emerging and Newly Identified Health Risks) Scientific opinion on the Safety of Poly Implant Prothèse (PIP) Silicone Breast Implants [Internet] Brussels: European Union; 2013. [cited 2014 May 12]. Available from: http://ec.europa.eu/health/scientific_committees/emerging/docs/scenihr_o....
-
- Berry MG, Stanek JJ. PIP implant biodurability: a post-publicity update. J Plast Reconstr Aesthet Surg. 2013;66:1174–1181. - PubMed
-
- Maijers MC, Niessen FB. Prevalence of rupture in poly implant Prothese silicone breast implants, recalled from the European market in 2010. Plast Reconstr Surg. 2012;129:1372–1378. - PubMed
-
- Les prothèses mammaires implantables PIP: état des lieux [Internet] Paris: ANSM; 2013 2012. [cited 2014 May 16]. Available from: http://ansm.sante.fr/content/download/47687/615167/version/2/file/PIP_Et....
Publication types
LinkOut - more resources
Full Text Sources
Other Literature Sources