Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2015 Apr;122(4):736-45.
doi: 10.1097/ALN.0000000000000601.

Randomized double-blinded comparison of norepinephrine and phenylephrine for maintenance of blood pressure during spinal anesthesia for cesarean delivery

Affiliations
Randomized Controlled Trial

Randomized double-blinded comparison of norepinephrine and phenylephrine for maintenance of blood pressure during spinal anesthesia for cesarean delivery

Warwick D Ngan Kee et al. Anesthesiology. 2015 Apr.

Abstract

Background: During spinal anesthesia for cesarean delivery, phenylephrine can cause reflexive decreases in maternal heart rate and cardiac output. Norepinephrine has weak β-adrenergic receptor agonist activity in addition to potent α-adrenergic receptor activity and therefore may be suitable for maintaining blood pressure with less negative effects on heart rate and cardiac output compared with phenylephrine.

Methods: In a randomized, double-blinded study, 104 healthy patients having cesarean delivery under spinal anesthesia were randomized to have systolic blood pressure maintained with a computer-controlled infusion of norepinephrine 5 μg/ml or phenylephrine 100 μg/ml. The primary outcome compared was cardiac output. Blood pressure heart rate and neonatal outcome were also compared.

Results: Normalized cardiac output 5 min after induction was greater in the norepinephrine group versus the phenylephrine group (median 102.7% [interquartile range, 94.3 to 116.7%] versus 93.8% [85.0 to 103.1%], P = 0.004, median difference 9.8%, 95% CI of difference between medians 2.8 to 16.1%). From induction until uterine incision, for norepinephrine versus phenylephrine, systolic blood pressure and stroke volume were similar, heart rate and cardiac output were greater, systemic vascular resistance was lower, and the incidence of bradycardia was smaller. Neonatal outcome was similar between groups.

Conclusions: When given by computer-controlled infusion during spinal anesthesia for cesarean delivery, norepinephrine was effective for maintaining blood pressure and was associated with greater heart rate and cardiac output compared with phenylephrine. Further work would be of interest to confirm the safety and efficacy of norepinephrine as a vasopressor in obstetric patients.

PubMed Disclaimer

Comment in

Publication types