Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 May;81(5):1228-33.
doi: 10.1016/j.gie.2014.10.024. Epub 2015 Jan 29.

Endoscopic biopsy technique in the diagnosis of celiac disease: one bite or two?

Affiliations

Endoscopic biopsy technique in the diagnosis of celiac disease: one bite or two?

Melissa Latorre et al. Gastrointest Endosc. 2015 May.

Abstract

Background: The diagnosis of celiac disease is dependent on the quality of biopsy specimens obtained at EGD. Endoscopists may obtain a single- or double-biopsy specimen with each pass of the forceps.

Objective: To compare the quality of biopsy specimens obtained with the single-biopsy and double-biopsy techniques.

Design: Prospective cohort study.

Setting: U.S. tertiary-care university hospital.

Patients: Patients undergoing upper endoscopy with confirmed, suspected, or unknown celiac disease status.

Interventions: Four biopsy specimens from the second portion of the duodenum: 2 by using the single-biopsy technique (1 bite per pass of the forceps) and an additional 2 by using the double-biopsy technique (2 bites per pass of the forceps). Specimens were blindly reviewed to determine orientation, consecutive crypt-to-villous units, and Marsh score.

Main outcome measurements: Proportion of well-oriented biopsy specimens.

Results: Patients (N = 86) were enrolled, 47% with known celiac disease, 36% with suspected celiac disease, and 17% with an unknown celiac disease status. Well-oriented biopsy specimens were noted in 66% of patients with the single-biopsy technique and 42% of patients with the double-biopsy technique (P < .01). Analysis of matched pairs showed improved orientation with the single-biopsy technique (odds ratio 3.1; 95% confidence interval, 1.5-7.1; P < .01). This persisted in subgroup analysis of patients with known celiac disease (P = .02), villous atrophy (P = .02), and a final diagnosis of celiac disease (P < .01).

Limitations: A single-center trial.

Conclusion: The single-biopsy technique improves the yield of well-oriented duodenal biopsy specimens. Endoscopists should consider taking only 1 biopsy specimen per pass of the forceps in patients undergoing biopsies of the duodenal mucosa.

PubMed Disclaimer

LinkOut - more resources