New and vintage solutions to enhance the plasma metabolome coverage by LC-ESI-MS untargeted metabolomics: the not-so-simple process of method performance evaluation
- PMID: 25642801
- DOI: 10.1021/ac503031d
New and vintage solutions to enhance the plasma metabolome coverage by LC-ESI-MS untargeted metabolomics: the not-so-simple process of method performance evaluation
Abstract
Although LC-MS untargeted metabolomics continues to expand into exiting research domains, methodological issues have not been solved yet by the definition of unbiased, standardized and globally accepted analytical protocols. In the present study, the response of the plasma metabolome coverage to specific methodological choices of the sample preparation (two SPE technologies, three sample-to-solvent dilution ratios) and the LC-ESI-MS data acquisition steps of the metabolomics workflow (four RP columns, four elution solvent combinations, two solvent quality grades, postcolumn modification of the mobile phase) was investigated in a pragmatic and decision tree-like performance evaluation strategy. Quality control samples, reference plasma and human plasma from a real nutrimetabolomic study were used for intermethod comparisons. Uni- and multivariate data analysis approaches were independently applied. The highest method performance was obtained by combining the plasma hybrid extraction with the highest solvent proportion during sample preparation, the use of a RP column compatible with 100% aqueous polar phase (Atlantis T3), and the ESI enhancement by using UHPLC-MS purity grade methanol as both organic phase and postcolumn modifier. Results led to the following considerations: submit plasma samples to hybrid extraction for removal of interfering components to minimize the major sample-dependent matrix effects; avoid solvent evaporation following sample extraction if loss in detection and peak shape distortion of early eluting metabolites are not noticed; opt for a RP column for superior retention of highly polar species when analysis fractionation is not feasible; use ultrahigh quality grade solvents and "vintage" analytical tricks such as postcolumn organic enrichment of the mobile phase to enhance ESI efficiency. The final proposed protocol offers an example of how novel and old-fashioned analytical solutions may fruitfully cohabit in untargeted metabolomics protocols.
Similar articles
-
Enhancing coverage in LC-MS-based untargeted metabolomics by a new sample preparation procedure using mixed-mode solid-phase extraction and two derivatizations.Anal Bioanal Chem. 2019 Sep;411(23):6189-6202. doi: 10.1007/s00216-019-02010-x. Epub 2019 Aug 14. Anal Bioanal Chem. 2019. PMID: 31414155
-
Extending metabolome coverage for untargeted metabolite profiling of adherent cultured hepatic cells.Anal Bioanal Chem. 2016 Feb;408(4):1217-30. doi: 10.1007/s00216-015-9227-8. Epub 2016 Jan 14. Anal Bioanal Chem. 2016. PMID: 26769129
-
LC-MS analysis of the plasma metabolome--a novel sample preparation strategy.J Chromatogr B Analyt Technol Biomed Life Sci. 2015 Jan 26;978-979:83-8. doi: 10.1016/j.jchromb.2014.11.033. Epub 2014 Dec 8. J Chromatogr B Analyt Technol Biomed Life Sci. 2015. PMID: 25531874
-
A review of nanoscale LC-ESI for metabolomics and its potential to enhance the metabolome coverage.Talanta. 2018 May 15;182:380-390. doi: 10.1016/j.talanta.2018.01.084. Epub 2018 Feb 5. Talanta. 2018. PMID: 29501168 Review.
-
Mass spectrometry-based holistic analytical approaches for metabolite profiling in systems biology studies.Mass Spectrom Rev. 2011 Sep-Oct;30(5):884-906. doi: 10.1002/mas.20306. Epub 2011 Mar 7. Mass Spectrom Rev. 2011. PMID: 21384411 Review.
Cited by
-
Metabolomic Workflow for the Accurate and High-Throughput Exploration of the Pathways of Tryptophan, Tyrosine, Phenylalanine, and Branched-Chain Amino Acids in Human Biofluids.J Proteome Res. 2022 May 6;21(5):1262-1275. doi: 10.1021/acs.jproteome.1c00946. Epub 2022 Apr 5. J Proteome Res. 2022. PMID: 35380444 Free PMC article.
-
Comparison between 5 extractions methods in either plasma or serum to determine the optimal extraction and matrix combination for human metabolomics.Cell Mol Biol Lett. 2023 May 20;28(1):43. doi: 10.1186/s11658-023-00452-x. Cell Mol Biol Lett. 2023. PMID: 37210499 Free PMC article.
-
Development of an Untargeted LC-MS Metabolomics Method with Postcolumn Infusion for Matrix Effect Monitoring in Plasma and Feces.J Am Soc Mass Spectrom. 2024 Mar 6;35(3):590-602. doi: 10.1021/jasms.3c00418. Epub 2024 Feb 21. J Am Soc Mass Spectrom. 2024. PMID: 38379502 Free PMC article.
-
Removal of multiple lipids from human plasma using a hydroxyl-functionalized covalent organic framework aerogel as a new sorbent.Mikrochim Acta. 2023 May 15;190(6):222. doi: 10.1007/s00604-023-05770-7. Mikrochim Acta. 2023. PMID: 37184589
-
Compensate for or Minimize Matrix Effects? Strategies for Overcoming Matrix Effects in Liquid Chromatography-Mass Spectrometry Technique: A Tutorial Review.Molecules. 2020 Jul 3;25(13):3047. doi: 10.3390/molecules25133047. Molecules. 2020. PMID: 32635301 Free PMC article. Review.