Effect of watching 3-dimensional television on refractive error in children
- PMID: 25646061
- PMCID: PMC4309869
- DOI: 10.3341/kjo.2015.29.1.53
Effect of watching 3-dimensional television on refractive error in children
Abstract
Purpose: To investigate the effect of watching 3-dimensional (3D) television (TV) on refractive error in children.
Methods: Sixty healthy volunteers, aged 6 to 12 years, without any ocular abnormalities other than refractive error were recruited for this study. They watched 3D TV for 50 minutes at a viewing distance of 2.8 meters. The image disparity of the 3D contents was from -1 to 1 degree. Refractive errors were measured both before and immediately after watching TV and were rechecked after a 10-minute rest period. The refractive errors before and after watching TV were compared. The amount of refractive change was also compared between myopes and controls. The refractive error of the participants who showed a myopic shift immediately after watching TV were compared across each time point to assure that the myopic shift persisted after a 10-minute rest.
Results: The mean age of the participants was 9.23 ± 1.75 years. The baseline manifest refractive error was -1.70 ± 1.79 (-5.50 to +1.25) diopters. The refractive errors immediately after watching and after a 10-minute rest were -1.75 ± 1.85 and -1.69 ± 1.80 diopters, respectively, which were not different from the baseline values. Myopic participants (34 participants), whose spherical equivalent was worse than -0.75 diopters, also did not show any significant refractive change after watching 3D TV. A myopic shift was observed in 31 participants with a mean score of 0.29 ± 0.23 diopters, which resolved after a 10-minute rest.
Conclusions: Watching properly made 3D content on a 3D TV for 50 minutes with a 10-minute intermission at more than 2.8 meters of viewing distance did not affect the refractive error of children.
Keywords: Depth perception; Myopia; Refractive errors.
Conflict of interest statement
No potential conflict of interest relevant to this article was reported.
Figures
Similar articles
-
Three-dimensional display-induced transient myopia and the difference in myopic shift between crossed and uncrossed disparities.Invest Ophthalmol Vis Sci. 2012 Jul 27;53(8):5029-32. doi: 10.1167/iovs.12-9588. Invest Ophthalmol Vis Sci. 2012. PMID: 22761261
-
Effects of Head-Mounted Display on the Oculomotor System and Refractive Error in Normal Adolescents.J Pediatr Ophthalmol Strabismus. 2016 Jul 1;53(4):238-45. doi: 10.3928/01913913-20160511-01. Epub 2016 Jun 7. J Pediatr Ophthalmol Strabismus. 2016. PMID: 27281827
-
Changes in ocular parameters depending on the motion-in-depth of a three-dimensional display.Br J Ophthalmol. 2015 Dec;99(12):1706-12. doi: 10.1136/bjophthalmol-2014-306297. Epub 2015 May 29. Br J Ophthalmol. 2015. PMID: 26024674
-
Refractive error, binocular vision and accommodation of children with Down syndrome.Clin Exp Optom. 2015 Jan;98(1):3-11. doi: 10.1111/cxo.12232. Epub 2014 Nov 13. Clin Exp Optom. 2015. PMID: 25395109 Review.
-
Do reduced visual acuity and refractive error affect classroom performance?Clin Exp Optom. 2020 May;103(3):278-289. doi: 10.1111/cxo.12953. Epub 2019 Aug 22. Clin Exp Optom. 2020. PMID: 31441091 Review.
Cited by
-
The Magnitude of Refractive Error and Its Associated Factors Among Patients Visiting Ophthalmology Clinics in Southern Ethiopia, 2022.Clin Ophthalmol. 2023 Jun 23;17:1801-1811. doi: 10.2147/OPTH.S408610. eCollection 2023. Clin Ophthalmol. 2023. PMID: 37383841 Free PMC article.
-
Virtual reality training improves accommodative facility and accommodative range.Int J Ophthalmol. 2022 Jul 18;15(7):1116-1121. doi: 10.18240/ijo.2022.07.11. eCollection 2022. Int J Ophthalmol. 2022. PMID: 35919330 Free PMC article.
-
Prevalence and associated factors of refractive error among adults in South Ethiopia, a community-based cross-sectional study.PLoS One. 2024 Mar 25;19(3):e0298960. doi: 10.1371/journal.pone.0298960. eCollection 2024. PLoS One. 2024. PMID: 38527026 Free PMC article.
-
Refractive error and its associated factors among pregnant women attending antenatal care unit at the University of Gondar Comprehensive Specialized Hospital, Northwest Ethiopia.PLoS One. 2021 Feb 12;16(2):e0246174. doi: 10.1371/journal.pone.0246174. eCollection 2021. PLoS One. 2021. PMID: 33577552 Free PMC article.
-
Influence of virtual reality on visual parameters: immersive versus non-immersive mode.BMC Ophthalmol. 2020 May 24;20(1):200. doi: 10.1186/s12886-020-01471-4. BMC Ophthalmol. 2020. PMID: 32448140 Free PMC article.
References
-
- Yano S, Ide S, Mitsuhashi T, Thwaites H. A study of visual fatigue and visual comfort for 3D HDTV/HDTV images. Displays. 2002;23:191–201.
-
- Schor CM, Tsuetaki TK. Fatigue of accommodation and vergence modifies their mutual interactions. Invest Ophthalmol Vis Sci. 1987;28:1250–1259. - PubMed
-
- Lambooij M, Fortuin M, Heynderickx I, Ijsselsteijn W. Visual discomfort and visual fatigue of stereoscopic displays: a review. J Imaging Sci Technol. 2009;53:30201–30214.
-
- Kim SH, Suh YW, Song JS, et al. Clinical research on the ophthalmic factors affecting 3D asthenopia. J Pediatr Ophthalmol Strabismus. 2012;49:248–253. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical