Effect of potting technique on the measurement of six degree-of-freedom viscoelastic properties of human lumbar spine segments
- PMID: 25646970
- DOI: 10.1115/1.4029698
Effect of potting technique on the measurement of six degree-of-freedom viscoelastic properties of human lumbar spine segments
Abstract
Polymethyl methacrylate (PMMA) and Wood's Metal are fixation media for biomechanical testing; however, the effect of each potting medium on the measured six degree-of-freedom (DOF) mechanical properties of human lumbar intervertebral discs is unknown. The first aim of this study was to compare the measured 6DOF elastic and viscoelastic properties of the disc when embedded in PMMA compared to repotting in Wood's Metal. The second aim was to compare the surface temperature of the disc when potted with PMMA and Wood's Metal. Six human lumbar functional spinal units (FSUs) were first potted in PMMA, and subjected to overnight preload in a saline bath at 37 °C followed by five haversine loading cycles at 0.1 Hz in each of 6DOF loading directions (compression, left/right lateral bending, flexion, extension, left/right axial rotation, anterior/posterior, and lateral shear). Each specimen was then repotted in Wood's Metal and subjected to a 2-h re-equilibrating preload followed by repeating the same 6DOF tests. Outcome measures of stiffness and phase angle were calculated from the final loading cycle in each DOF and were expressed as normalized percentages relative to PMMA (100%). Disc surface temperatures (anterior, left/right lateral) were measured during potting. Paired t-tests (with alpha adjusted for multiple DOF) were conducted to compare the differences in each outcome parameter between PMMA and Wood's Metal. No significant differences in stiffness or phase angle were found between PMMA and Wood's Metal. On average, the largest trending differences were found in the shear DOFs for both stiffness (approximately 35% greater for Wood's Metal compared to PMMA) and phase angle (approximately 15% greater for Wood's Metal). A significant difference in disc temperature was found at the anterior surface after potting with Wood's Metal compared to PMMA, which did not exceed 26 °C. Wood's Metal is linear elastic, stiffer than PMMA and may reduce measurement artifact of potting medium, particularly in the shear directions. Furthermore, it is easier to remove than PMMA, reuseable, and cost effective.
Similar articles
-
The effect of six degree of freedom loading sequence on the in-vitro compressive properties of human lumbar spine segments.J Biomech. 2016 Oct 3;49(14):3407-3414. doi: 10.1016/j.jbiomech.2016.09.009. Epub 2016 Sep 14. J Biomech. 2016. PMID: 27663622
-
Evaluation of filler materials used for uniform load distribution at boundaries during structural biomechanical testing of whole vertebrae.J Biomech Eng. 2006 Feb;128(1):161-5. doi: 10.1115/1.2133770. J Biomech Eng. 2006. PMID: 16532630
-
Effect of degeneration on the six degree of freedom mechanical properties of human lumbar spine segments.J Orthop Res. 2016 Aug;34(8):1399-409. doi: 10.1002/jor.23334. Epub 2016 Jun 28. J Orthop Res. 2016. PMID: 27291789
-
[Multi-segment ventral stabilization of the lumbar spine: a comparative biomechanical study].Z Orthop Ihre Grenzgeb. 1995 May-Jun;133(3):242-8. doi: 10.1055/s-2008-1039444. Z Orthop Ihre Grenzgeb. 1995. PMID: 7610706 Review. German.
-
Robert Williams Wood: pioneer of invisible light.Photodermatol Photoimmunol Photomed. 2016 Mar;32(2):60-5. doi: 10.1111/phpp.12235. Epub 2016 Jan 29. Photodermatol Photoimmunol Photomed. 2016. PMID: 26752503 Review.
Cited by
-
Influence of testing environment and loading rate on intervertebral disc compressive mechanics: An assessment of repeatability at three different laboratories.JOR Spine. 2020 Jul 15;3(3):e21110. doi: 10.1002/jsp2.1110. eCollection 2020 Sep. JOR Spine. 2020. PMID: 33015585 Free PMC article.
-
Design Requirements for Annulus Fibrosus Repair: Review of Forces, Displacements, and Material Properties of the Intervertebral Disk and a Summary of Candidate Hydrogels for Repair.J Biomech Eng. 2016 Feb;138(2):021007. doi: 10.1115/1.4032353. J Biomech Eng. 2016. PMID: 26720265 Free PMC article.
-
Can axial loading restore in vivo disc geometry, opening pressure, and T2 relaxation time?JOR Spine. 2024 Apr 25;7(2):e1322. doi: 10.1002/jsp2.1322. eCollection 2024 Jun. JOR Spine. 2024. PMID: 38666074 Free PMC article.
-
Location of pedicle screw hold in relation to bone quality and loads.Front Bioeng Biotechnol. 2022 Sep 2;10:953119. doi: 10.3389/fbioe.2022.953119. eCollection 2022. Front Bioeng Biotechnol. 2022. PMID: 36118575 Free PMC article.
-
Spine biomechanical testing methodologies: The controversy of consensus vs scientific evidence.JOR Spine. 2021 Jan 5;4(1):e1138. doi: 10.1002/jsp2.1138. eCollection 2021 Mar. JOR Spine. 2021. PMID: 33778410 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources