Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 May;34(5):1031-7.
doi: 10.1007/s10096-015-2319-8. Epub 2015 Feb 4.

High medical impact of implementing the new polymeric bead-based BacT/ALERT® FAPlus and FNPlus blood culture bottles in standard care

Affiliations

High medical impact of implementing the new polymeric bead-based BacT/ALERT® FAPlus and FNPlus blood culture bottles in standard care

R Amarsy-Guerle et al. Eur J Clin Microbiol Infect Dis. 2015 May.

Abstract

Blood culture (BC) efficiency is critical for the diagnosis of bloodstream infection (BSI). We evaluated the impact on standard care of implementing the new BacT/ALERT® FAPlus and FNPlus BC bottles containing antibiotic-binding polymeric beads. We measured positivity rates and time to detection (TTD) during the first 10 months of implementation (PF) and during the previous 10-month period (PS) during which we were using standard aerobic (SA) or standard anaerobic (SN) BC bottles. For each period, the same number of consecutive patients (n = 3,918) was included. Per patient, a median of 1 BC set (1 aerobic and 1 anaerobic bottles) has been sampled. A higher positivity rate was measured during PF than PS when counting per BC bottle (7.0 % vs 5.8 % with 1,456 and 1,237 positive bottles respectively, P < 0.0001) and per BC set (9.6 % vs 7.8 % with 995 and 832 positive BC sets respectively, P < 0.0001). In PF, an increased number of cases due to staphylococci (P < 0.0001) and to Gram-negative bacilli (P < 0.005) was observed, whereas the contamination rate was similar during the two periods (2.4 % of BC sets in PF and 2.3 % in PS). Although antibiotic consumption and medical activity were similar during the two periods, BSI case detection increased from 2.2 to 2.6 per 1,000 hospital-days, especially in intensive care units (ICU; 35.1 to 55.7). Mean TTD for pathogenic microorganisms was significantly shorter in PF than in PS (15.5 h vs 18.0 h, P < 0.01). In conclusion, the use of the new FAPlus/FNPlus BC bottles improved the diagnosis of bacteremia in our hospital, especially in ICU patients.

PubMed Disclaimer

References

    1. J Clin Microbiol. 2014 Oct;52(10):3558-67 - PubMed
    1. J Clin Microbiol. 2014 Mar;52(3):839-43 - PubMed
    1. J Clin Microbiol. 2002 Jul;40(7):2437-44 - PubMed
    1. Clin Infect Dis. 2013 Aug;57(4):e22-e121 - PubMed
    1. Clin Microbiol Rev. 2006 Oct;19(4):788-802 - PubMed

Publication types

LinkOut - more resources