Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 May;56(5):2848-54.
doi: 10.1167/iovs.14-15757.

Dynamic change of optical quality in patients with dry eye disease

Affiliations

Dynamic change of optical quality in patients with dry eye disease

Chia-Hsuan Tan et al. Invest Ophthalmol Vis Sci. 2015 May.

Abstract

Purpose: To evaluate the dynamic changes of optical quality in patients with dry eye disease (DED) by using a double-pass system.

Methods: Fifty-six patients with DED and 35 control subjects were included in this study. Each patient underwent an evaluation of the ocular surface, using the Ocular Surface Disease Index, tear film breakup time (TBUT), corneal and conjunctival staining (Oxford scale), and Schirmer I test. Using the tear film analysis program of the Optical Quality Analysis System, we recorded the objective scatter index (OSI) every 0.5 seconds within a 20-second period with the subjects asked to blink freely. Several parameters were established to evaluate the dynamic alterations of optical quality and the effects of blinks: OSI standard deviation (SD), ΔOSI, ΔOSI/time, blinking change (BC), blinking frequency (BF), and tolerant limitation (TL).

Results: Patients with DED had significant alterations of optical quality compared to control subjects. The ΔOSI, ΔOSI/time, BC, and BF were significantly higher and TL was significantly lower in DED patients than controls. Furthermore, the ΔOSI and ΔOSI/time were also significantly higher in patients with severe DED than patients with mild disease. In univariate analysis, both TBUT and corneal staining were correlated with ΔOSI, ΔOSI/time, and BC. In multivariate analysis, ΔOSI/time was correlated to the corneal staining score.

Conclusions: The double-pass system allowed the monitoring of the dynamic changes of optical quality in patients with DED. Optical quality should be evaluated in patients with DED because these alterations cannot be determined from the classical DED clinical tests.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources