Complications of radial head prostheses
- PMID: 25655903
- DOI: 10.1007/s00264-015-2689-7
Complications of radial head prostheses
Abstract
Radial head prostheses are indicated for treatment of complex radial head fractures not amenable for fixation. After the initial experience with silastic implants, metallic or pyrocarbon arthroplasty have been used for 20 years. Little is known about complications related to these implants. Main complications are related to loosening whether they are cemented or not cemented. Hypotheses have been proposed like inadequate stem design, insufficient cement technique, stress shielding, and foreign body reactions secondary to polyethylene wear. Pain and stiffness are other common complications often related to oversized radial head component or overstuffing of the joint with excessive lengthening of the radius. Instability can be another complication in the context of more complex trauma with lateral collateral ligament complex lesion and coronoid fracture. Fixation of the coronoid fracture, reinsertion of the lateral collateral ligament complex, and the use of monobloc radial head prosthesis are recommended to stabilize the joint. Finally, osteoarthritis is common with follow-up.
Similar articles
-
Radial head prosthesis: surgical tips and tricks.Musculoskelet Surg. 2017 Dec;101(Suppl 2):187-196. doi: 10.1007/s12306-017-0504-x. Epub 2017 Oct 9. Musculoskelet Surg. 2017. PMID: 28994021 Review.
-
[Primary radial head arthroplasty in trauma : Complications].Orthopade. 2016 Oct;45(10):853-60. doi: 10.1007/s00132-016-3330-1. Orthopade. 2016. PMID: 27600571 Review. German.
-
Radial head arthroplasty: state of the art.J Am Acad Orthop Surg. 2014 Oct;22(10):633-42. doi: 10.5435/JAAOS-22-10-633. J Am Acad Orthop Surg. 2014. PMID: 25281258 Review.
-
Tight-fitting radial head prosthesis: does stem size help prevent painful loosening?Int Orthop. 2018 Jan;42(1):161-167. doi: 10.1007/s00264-017-3644-6. Epub 2017 Sep 21. Int Orthop. 2018. PMID: 28936610
-
Short to midterm outcomes of one hundred and seventy one MoPyC radial head prostheses: meta-analysis.Int Orthop. 2018 Oct;42(10):2403-2411. doi: 10.1007/s00264-018-4070-0. Epub 2018 Jul 30. Int Orthop. 2018. PMID: 30062566
Cited by
-
A systematic review and meta-analysis on different stem fixation methods of radial head prostheses during long-term follow-up.Front Bioeng Biotechnol. 2022 Nov 1;10:1041531. doi: 10.3389/fbioe.2022.1041531. eCollection 2022. Front Bioeng Biotechnol. 2022. PMID: 36394008 Free PMC article.
-
Does stress shielding after radial head arthroplasty affect functional outcomes?Eur J Orthop Surg Traumatol. 2023 Jul;33(5):1591-1598. doi: 10.1007/s00590-022-03315-x. Epub 2022 Jun 28. Eur J Orthop Surg Traumatol. 2023. PMID: 35763223
-
Comparison between radial head arthroplasty and open reduction and internal fixation in patients with radial head fractures (modified Mason type III and IV): a meta-analysis.Eur J Orthop Surg Traumatol. 2016 Apr;26(3):283-91. doi: 10.1007/s00590-016-1739-1. Epub 2016 Jan 21. Eur J Orthop Surg Traumatol. 2016. PMID: 26794323
-
Relationship between measurements of ipsilateral capitellum and prosthetic radial head size.J Orthop Surg Res. 2022 Nov 19;17(1):496. doi: 10.1186/s13018-022-03393-x. J Orthop Surg Res. 2022. PMID: 36403037 Free PMC article.
-
Anthropometric study of the proximal radius: does radial head implant fit in all cases?Int Orthop. 2015 Aug;39(8):1553-61. doi: 10.1007/s00264-015-2773-z. Epub 2015 May 10. Int Orthop. 2015. PMID: 25957588
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical