Predictive factors for limb occlusions after endovascular aneurysm repair
- PMID: 25656594
- DOI: 10.1016/j.jvs.2014.11.084
Predictive factors for limb occlusions after endovascular aneurysm repair
Abstract
Objective: Greater flexibility and smaller sizes for introducer sheaths in the newest stent grafts increase the feasibility of endovascular aneurysm repair but raise concerns about long-term limb patency. The aim of the study was to determine the incidence of and predictive factors for limb occlusion after use of the Endurant stent graft (Medtronic Inc, Minneapolis, Minn) for abdominal aortic aneurysm.
Methods: The Endurant Stent Graft Natural Selection Global Postmarket Registry (ENGAGE) prospectively included 1143 patients treated with bifurcated devices who were observed for up to 2 years. Limb occlusions were evidenced by computed tomography, angiography, or ultrasound. To predict stent graft limb occlusion, a two-step model-building technique was applied. We first identified predictors from a total of 47 covariates obtained at baseline and in the periprocedural period. Subsequently, we reduced the set of potential predictors to key factors that are clinically meaningful. To handle large numbers of covariates, we used the Classification And Regression Tree (CART) method.
Results: Forty-two stent graft limbs occluded in 39 patients (3.4% of the patients). At 2 years, the rate of freedom from stent graft limb occlusion calculated by Kaplan-Meier plot was 97.9% (standard error [SE], 0.33%). Of the 42 occlusions, 13 (31%) were observed within 30 days and 30 (71%) within 6 months. The strongest independent predictors were distal landing zone on the external iliac artery, external iliac artery diameter ≤10 mm, and kinking. High-risk vs low-risk patients were identified according to a decision tree based on the strongest predictors. Freedom from stent graft limb occlusion was 96.1% (SE, 0.64%) in high-risk patients vs 99.6% (SE, 0.19%) in low-risk patients.
Conclusions: After Endurant stent grafting, the incidence of limb occlusion was low. Classifying patients as high risk vs low risk according to the algorithm used in this study may help define specific strategies to prevent limb occlusion and improve the overall results of endovascular aneurysm repair using the latest generation of stent grafts.
Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Similar articles
-
One-year multicenter results of 100 abdominal aortic aneurysm patients treated with the Endurant stent graft.J Vasc Surg. 2011 Sep;54(3):609-15. doi: 10.1016/j.jvs.2011.02.053. Epub 2011 May 28. J Vasc Surg. 2011. PMID: 21620631
-
Predicting iliac limb occlusions after bifurcated aortic stent grafting: anatomic and device-related causes.J Vasc Surg. 2002 Oct;36(4):679-84. J Vasc Surg. 2002. PMID: 12368725
-
Adjunctive iliac stents reduce the risk of stent-graft limb occlusion following endovascular aneurysm repair with the Zenith stent-graft.J Endovasc Ther. 2010 Feb;17(1):108-14. doi: 10.1583/09-2854.1. J Endovasc Ther. 2010. PMID: 20199276
-
Worldwide experience with the Endurant Stent graft: review of the literature.J Cardiovasc Surg (Torino). 2011 Oct;52(5):669-81. Epub 2011 Jul 28. J Cardiovasc Surg (Torino). 2011. PMID: 21796091 Review.
-
Impact of Post-EVAR Graft Limb Kinking in EVAR Limb Occlusion: Aetiology, Early Diagnosis, and Management.Eur J Vasc Endovasc Surg. 2019 Nov;58(5):681-689. doi: 10.1016/j.ejvs.2019.03.019. Epub 2019 Sep 9. Eur J Vasc Endovasc Surg. 2019. PMID: 31514990
Cited by
-
Predictive Factors for Iliac Limb Occlusions After Endovascular Abdominal Aneurysm Repair: Determined from Aortoiliac Anatomy, Endovascular Procedures, and Aneurysmal Remodeling.Ther Clin Risk Manag. 2024 May 20;20:297-311. doi: 10.2147/TCRM.S459594. eCollection 2024. Ther Clin Risk Manag. 2024. PMID: 38799513 Free PMC article.
-
Thrombotic Occlusion of Stent Graft Limbs due to Severe Angulation of Aortic Neck in Endovascular Repair of Abdominal Aortic Aneurysm.Korean Circ J. 2016 Sep;46(5):727-729. doi: 10.4070/kcj.2016.46.5.727. Epub 2016 Aug 16. Korean Circ J. 2016. PMID: 27721866 Free PMC article.
-
Impact of Antithrombotic Therapy on Thrombotic and Bleeding Complications after Elective Endovascular Repair of Abdominal Aortic Aneurysms.Cardiovasc Intervent Radiol. 2025 Feb;48(2):157-166. doi: 10.1007/s00270-024-03946-z. Epub 2025 Jan 16. Cardiovasc Intervent Radiol. 2025. PMID: 39821653 Free PMC article.
-
A new approach for the pre-clinical optimization of a spatial configuration of bifurcated endovascular prosthesis placed in abdominal aortic aneurysms.PLoS One. 2017 Aug 9;12(8):e0182717. doi: 10.1371/journal.pone.0182717. eCollection 2017. PLoS One. 2017. PMID: 28793343 Free PMC article.
-
Bare metal stent application to prevent limb occlusion in iliac arteries with severe tortuosity during an endovascular aneurysm repair: a cohort study.Front Cardiovasc Med. 2024 Dec 4;11:1401929. doi: 10.3389/fcvm.2024.1401929. eCollection 2024. Front Cardiovasc Med. 2024. PMID: 39697301 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical