Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Apr;21(4):372-8.
doi: 10.1016/j.cmi.2014.11.009. Epub 2014 Nov 20.

Matrix-assisted laser desorption ionization time-of-flight mass spectrometry for the rapid identification of yeasts causing bloodstream infections

Affiliations

Matrix-assisted laser desorption ionization time-of-flight mass spectrometry for the rapid identification of yeasts causing bloodstream infections

A K Ghosh et al. Clin Microbiol Infect. 2015 Apr.

Abstract

Few studies have systematically standardised and evaluated matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) for identification of yeasts from bloodstream infections. This is rapidly becoming pertinent for early identification of yeasts and appropriate antifungal therapy. We used 354 yeast strains identified by polymerase chain reaction (PCR) sequencing for standardisation and 367 blind clinical strains for validation of our MALDI-TOF MS protocols. We also evaluated different sample preparation methods and found the on-plate formic acid extraction method as most cost- and time-efficient. The MALDI-TOF assay correctly identified 98.9% of PCR-sequenced yeasts. Novel main spectrum projections (MSP) were developed for Candida auris, C. viswanathii and Kodamaea ohmeri, which were missing from the Bruker MALDI-TOF MS database. Spectral cut-offs computed by receiver operating characteristics (ROC) analysis showed 99.4% to 100% accuracy at a log score of ≥ 1.70 for C. tropicalis, C. parapsilosis, C. pelliculosa, C. orthopsilosis, C. albicans, C. rugosa, C. guilliermondii, C. lipolytica, C. metapsilosis, C. nivariensis. The differences in the species-specific scores of our standardisation and blind validation strains were not statistically significant, implying the optimal performance of our test protocol. The MSPs of the three new species also were validated. We conclude that MALDI-TOF MS is a rapid, accurate and reliable tool for identification of bloodstream yeasts. With proper standardisation, validation and regular database expansion, its efficiency can be further enhanced.

Keywords: Bloodstream infection; Candida; matrix-assisted laser desorption ionization time-of-flight mass spectrometry; rapid diagnosis; yeast.

PubMed Disclaimer

Publication types

MeSH terms