. 2015 May;53(5):381-92.
doi: 10.1007/s11517-015-1247-1. Epub 2015 Feb 8.

Biomechanical study of different plate configurations for distal humerus osteosynthesis

Affiliations

Biomechanical study of different plate configurations for distal humerus osteosynthesis

M Bogataj et al. Med Biol Eng Comput. 2015 May.

Abstract

Fractures of the distal humerus are most commonly fixed by open reduction and internal fixation, using plates and screws, either in a locking or in a non-locking construct. Three different plating systems are commonly used in practice. The most important differences between them are in plate orientation, which affects both the rigidity of the osteosynthesis and invasiveness of the surgical procedure. Unfortunately, there is no common agreement between surgeons about which plate configuration brings the best clinical outcome. In this study, we investigate the theoretical rigidity of plate osteosyntheses considering two types of AO/ASIF configurations (90° angle between plates), Mayo clinic (Acumed) configuration (180° between plates) and dorsal fixation of both plates. We also compared the results for cases with and without contact between the bone fragments. In the case of no bone contact, the Mayo clinic plate configuration is found to be the most rigid, followed by both AO/ASIF plate configurations, and the least rigid system is the Korosec plate configuration. On the other hand, no significant differences between all types of fixation configurations are found in cases with contact in-between the bone fragments. Our findings show that this contact is very important and can compensate for the lack of load carrying capacity of the implants. This could therefore incite other implant fixation solutions, leading to less invasive surgical procedures and consequently improved clinical outcome.

PubMed Disclaimer

References

    1. J Biomech. 2012 Jun 1;45(9):1712-6 - PubMed
    1. Clin Biomech (Bristol, Avon). 2007 Jun;22(5):510-7 - PubMed
    1. J Shoulder Elbow Surg. 2010 Jan;19(1):2-9 - PubMed
    1. Knee Surg Sports Traumatol Arthrosc. 1996;3(4):226-9 - PubMed
    1. J Orthop Trauma. 2004 May-Jun;18(5):286-93 - PubMed

Publication types

LinkOut - more resources