Methane emissions from natural gas compressor stations in the transmission and storage sector: measurements and comparisons with the EPA greenhouse gas reporting program protocol
- PMID: 25668051
- DOI: 10.1021/es5060258
Methane emissions from natural gas compressor stations in the transmission and storage sector: measurements and comparisons with the EPA greenhouse gas reporting program protocol
Abstract
Equipment- and site-level methane emissions from 45 compressor stations in the transmission and storage (T&S) sector of the US natural gas system were measured, including 25 sites required to report under the EPA greenhouse gas reporting program (GHGRP). Direct measurements of fugitive and vented sources were combined with AP-42-based exhaust emission factors (for operating reciprocating engines and turbines) to produce a study onsite estimate. Site-level methane emissions were also concurrently measured with downwind-tracer-flux techniques. At most sites, these two independent estimates agreed within experimental uncertainty. Site-level methane emissions varied from 2-880 SCFM. Compressor vents, leaky isolation valves, reciprocating engine exhaust, and equipment leaks were major sources, and substantial emissions were observed at both operating and standby compressor stations. The site-level methane emission rates were highly skewed; the highest emitting 10% of sites (including two superemitters) contributed 50% of the aggregate methane emissions, while the lowest emitting 50% of sites contributed less than 10% of the aggregate emissions. Excluding the two superemitters, study-average methane emissions from compressor housings and noncompressor sources are comparable to or lower than the corresponding effective emission factors used in the EPA greenhouse gas inventory. If the two superemitters are included in the analysis, then the average emission factors based on this study could exceed the EPA greenhouse gas inventory emission factors, which highlights the potentially important contribution of superemitters to national emissions. However, quantification of their influence requires knowledge of the magnitude and frequency of superemitters across the entire T&S sector. Only 38% of the methane emissions measured by the comprehensive onsite measurements were reportable under the new EPA GHGRP because of a combination of inaccurate emission factors for leakers and exhaust methane, and various exclusions. The bias is even larger if one accounts for the superemitters, which were not captured by the onsite measurements. The magnitude of the bias varied from site to site by site type and operating state. Therefore, while the GHGRP is a valuable new source of emissions information, care must be taken when incorporating these data into emission inventories. The value of the GHGRP can be increased by requiring more direct measurements of emissions (as opposed to using counts and emission factors), eliminating exclusions such as rod-packing vents on pressurized reciprocating compressors in standby mode under Subpart-W, and using more appropriate emission factors for exhaust methane from reciprocating engines under Subpart-C.
Similar articles
-
Methane Emissions from the Natural Gas Transmission and Storage System in the United States.Environ Sci Technol. 2015 Aug 4;49(15):9374-83. doi: 10.1021/acs.est.5b01669. Epub 2015 Jul 21. Environ Sci Technol. 2015. PMID: 26195284
-
Methane Exhaust Measurements at Gathering Compressor Stations in the United States.Environ Sci Technol. 2021 Jan 19;55(2):1190-1196. doi: 10.1021/acs.est.0c05492. Epub 2021 Jan 7. Environ Sci Technol. 2021. PMID: 33410668
-
Methane Emissions from Leak and Loss Audits of Natural Gas Compressor Stations and Storage Facilities.Environ Sci Technol. 2015 Jul 7;49(13):8132-8. doi: 10.1021/es506163m. Environ Sci Technol. 2015. PMID: 26148551
-
Emissions from oil and gas operations in the United States and their air quality implications.J Air Waste Manag Assoc. 2016 Jun;66(6):549-75. doi: 10.1080/10962247.2016.1171263. J Air Waste Manag Assoc. 2016. PMID: 27249104 Review.
-
Methodologies for measuring fugitive methane emissions from landfills - A review.Waste Manag. 2019 Mar 15;87:835-859. doi: 10.1016/j.wasman.2018.12.047. Epub 2019 Jan 16. Waste Manag. 2019. PMID: 30660403 Review.
Cited by
-
An enhanced procedure for urban mobile methane leak detection.Heliyon. 2020 Oct 9;6(10):e04876. doi: 10.1016/j.heliyon.2020.e04876. eCollection 2020 Oct. Heliyon. 2020. PMID: 33088932 Free PMC article.
-
Detection Limits of Optical Gas Imaging for Natural Gas Leak Detection in Realistic Controlled Conditions.Environ Sci Technol. 2020 Sep 15;54(18):11506-11514. doi: 10.1021/acs.est.0c01285. Epub 2020 Aug 26. Environ Sci Technol. 2020. PMID: 32786569 Free PMC article.
-
Quantification of natural gas and other hydrocarbons from production sites in northern West Virginia using tracer flux ratio methodology.Atmos Environ X. 2023 Aug 1;19:1-8. doi: 10.1016/j.aeaoa.2023.100220. Atmos Environ X. 2023. PMID: 37538994 Free PMC article.
-
A review of the public health impacts of unconventional natural gas development.Environ Geochem Health. 2018 Feb;40(1):1-57. doi: 10.1007/s10653-016-9898-x. Epub 2016 Dec 5. Environ Geochem Health. 2018. PMID: 27921191 Review.
-
Assessing a low-cost methane sensor quantification system for use in complex rural and urban environments.Atmos Meas Tech. 2018 Jun;11(6):3569-3594. doi: 10.5194/amt-11-3569-2018. Epub 2018 Jun 20. Atmos Meas Tech. 2018. PMID: 33442426 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials