. 2014 Mar 8:3:132.
doi: 10.1186/2193-1801-3-132. eCollection 2014.

Treatment outcomes of carotid artery stenting with two types of distal protection filter device

Affiliations

Treatment outcomes of carotid artery stenting with two types of distal protection filter device

Minoru Iko et al. Springerplus. .

Abstract

Purpose: Preventing cerebral embolism from debris produced during carotid artery stenting (CAS) is important. This study compared the treatment outcomes of CAS using two types of filter-based embolic protection devices currently in use in Japan.

Materials and methods: We assessed 121 consecutive cases of CAS performed with FilterWire EZ™ between July 2010 and November 2012 and 37 consecutive cases of CAS performed with the Spider FX™ between November 2012 and June 2013. A Carotid Wallstent™ was used in all cases. The incidence of positive lesions on diffusion-weighted magnetic resonance imaging (DWI) and stroke were compared between the groups.

Results: Postoperative DWI-positive lesions were observed in 38 (31.4%) and 14 (37.8%) patients in the FilterWire and Spider groups, respectively. In the FilterWire group, complications were transient ischemic attacks in 3 (2.5%) patients, cerebral infarction in 2 (1.7%) patients (1 patient each with minor and major stroke), and cerebral hemorrhage due to hyperperfusion syndrome in 1 (0.8%) patient. In the Spider group, except for cerebral infarction (minor stroke) in 1 (2.7%) patient, no complications were observed. No significant differences were observed in the incidence of complications between the groups.

Conclusion: FilterWire EZ and Spider FX are comparable in terms of treatment outcome.

Keywords: Carotid artery stenting; Cerebral infarction; Diffusion-weighted magnetic resonance imaging; Distal protection filter device.

PubMed Disclaimer

References

    1. Bates ER, Babb JD, Casey DE, Jr, Cates CU, Duckwiler GR, Feldman TE, Gray WA, Ouriel K, Peterson ED, Rosenfield K, Rundback JH, Safian RD, Sloan MA, White CJ. ACCF/SCAI/SVMB/SIR/ASITN 2007 clinical expert consensus document on carotid stenting: a report of the American College of Cardiology Foundation Task Force on Clinical Expert Consensus Documents (ACCF/SCAI/SVMB/SIR/ASITN Clinical Expert Consensus Document Committee on Carotid Stenting) J Am Coll Cardiol. 2007;49(1):126–170. doi: 10.1016/j.jacc.2006.10.021. - DOI - PubMed
    1. Brott TG, Hobson RW, 2nd, Howard G, Roubin GS, Clark WM, Brooks W, Mackey A, Hill MD, Leimgruber PP, Sheffet AJ, Howard VJ, Moore WS, Voeks JH, Hopkins LN, Cutlip DE, Cohen DJ, Popma JJ, Ferguson RD, Cohen SN, Blackshear JL, Silver FL, Mohr JP, Lal BK, Meschia JF, CREST Investigators Stenting versus endarterectomy for treatment of carotid-artery stenosis. N Engl J Med. 2010;363(1):11–23. doi: 10.1056/NEJMoa0912321. - DOI - PMC - PubMed
    1. Casserly IP, Abou-Chebl A, Fathi RB, Lee DS, Saw J, Exaire JE, Kapadia SR, Bajzer CT, Yadav JS. Slow-flow phenomenon during carotid artery intervention with embolic protection devices: predictors and clinical outcome. J Am Coll Cardiol. 2005;46(8):1466–1472. doi: 10.1016/j.jacc.2005.05.082. - DOI - PubMed
    1. Iko M, Tsutsumi M, Aikawa H, Matsumoto Y, Go Y, Nii K, Abe G, Ye I, Nomoto Y, Kazekawa K. Distal protection filter device efficacy with carotid artery stenting: comparison between a distal protection filter and a distal protection balloon. Jpn J Radiol. 2013;31(1):45–49. doi: 10.1007/s11604-012-0145-9. - DOI - PubMed
    1. Iyer V, de Donato G, Deloose K, Peeters P, Castriota F, Cremonesi A, Setacci C, Bosiers M. The type of embolic protection does not influence the outcome in carotid artery stenting. J Vasc Surg. 2007;46(2):251–256. doi: 10.1016/j.jvs.2007.04.053. - DOI - PubMed

LinkOut - more resources