Comparison of treatment of oblique and spiral metacarpal and phalangeal fractures with mini plate plus screw or screw only
- PMID: 25682110
- DOI: 10.1007/s00402-015-2164-3
Comparison of treatment of oblique and spiral metacarpal and phalangeal fractures with mini plate plus screw or screw only
Abstract
Introduction: We aimed to compare results of treatment of oblique-spiral metacarpal and phalangeal fractures with screw only or mini plate plus screw, respectively.
Methods: A total of 43 patients who were operated with a diagnosis of displaced, irreducible, unstable, rotational oblique-spiral metacarpal and proximal phalangeal fracture between 2007 and 2010 were included in this study. The mean age of patients with a phalangeal fracture was 33.8 years (range 20-50 years; 4 females, 18 males), and the mean age of patients with a metacarpal fracture was 29.6 years (range 18-45 years; 3 females, 18 males). Mini plate plus screw or screw only was used for internal fixation of these fractures. The patients were followed up for 19.2 ± 5.4 months in the phalangeal fracture group and 20.9 ± 7.3 months in metacarpal fracture group. Of the metacarpal fractures, 14 were oblique and 10 spiral, whereas 14 of the phalangeal fractures were oblique and 8 spiral. The patients were evaluated according to total range of motion of the finger, grasping strength and Q-DASH score.
Results: For patients treated with mini plate plus screw after metacarpal and phalangeal fractures, the time to return to work was significantly shorter in comparison to patients treated with screws only. There was no significant difference between patients with metacarpal fractures treated with mini plate plus screw and patients treated with screw only in terms of total range of motion and Q-DASH results at last on control examination, while results of patients with phalangeal fractures treated with screw only were significantly better. There was no significant difference between these two treatments in phalangeal fractures in terms of grasping strength of the finger in early (1st month) and late (last control examination), whereas patients with metacarpal fractures treated with mini plate plus screw reached higher grasping strength earlier.
Conclusion: Treatment with mini plate plus screw should be avoided in spiral and oblique phalangeal fractures, and fixation should be done with screw only with a short surgical incision and dissection. On the other hand, treatment with mini plate plus screw should be preferred in patients with spiral and oblique metacarpal fractures, especially in those who work in occupations requiring higher physical strength.
Similar articles
-
Comparison of AO Titanium Locking Plate and Screw Fixation versus Anterograde Intramedullary Fixation for Isolated Unstable Metacarpal and Phalangeal Fractures.Orthop Surg. 2016 Aug;8(3):316-22. doi: 10.1111/os.12271. Orthop Surg. 2016. PMID: 27627714 Free PMC article. Clinical Trial.
-
[Open reduction and low-profile plate and/or screw fixation in the treatment of phalangeal fractures].Acta Orthop Traumatol Turc. 2009 Aug-Oct;43(4):317-23. doi: 10.3944/AOTT.2009.317. Acta Orthop Traumatol Turc. 2009. PMID: 19809228 Turkish.
-
Predictors of the postoperative range of finger motion for comminuted periarticular metacarpal and phalangeal fractures treated with a titanium plate.Injury. 2012 Jun;43(6):940-5. doi: 10.1016/j.injury.2012.02.011. Epub 2012 Mar 28. Injury. 2012. PMID: 22459897
-
Extraarticular hand fractures in adults: a review of new developments.Clin Orthop Relat Res. 2006 Apr;445:133-45. doi: 10.1097/01.blo.0000205888.04200.c5. Clin Orthop Relat Res. 2006. PMID: 16505726 Review.
-
Fixation choices for closed simple unstable oblique phalangeal and metacarpal fractures.Hand Clin. 2006 Aug;22(3):287-95. doi: 10.1016/j.hcl.2006.02.018. Hand Clin. 2006. PMID: 16843795 Review.
Cited by
-
Clinical Outcomes of Retrograde Percutaneous Pinning for Shaft Fracture of Metacarpal Bone: A Case Series.J Orthop Case Rep. 2025 Apr;15(4):239-244. doi: 10.13107/jocr.2025.v15.i04.5510. J Orthop Case Rep. 2025. PMID: 40212503 Free PMC article.
-
[Percutaneous treatment of unstable fractures of the base of the middle phalanx : Technique according to Hintringer and Ender].Oper Orthop Traumatol. 2019 Oct;31(5):384-392. doi: 10.1007/s00064-019-0621-9. Epub 2019 Jul 25. Oper Orthop Traumatol. 2019. PMID: 31346631 Review. German.
-
Comparison of Miniplate and K-wire in the Treatment of Metacarpal and Phalangeal Fractures.Cureus. 2020 Feb 19;12(2):e7039. doi: 10.7759/cureus.7039. Cureus. 2020. PMID: 32211271 Free PMC article.
-
Comparative study of K-wire combined with screw vs. K-wire in the treatment of AO type B3.1 phalangeal fractures.BMC Musculoskelet Disord. 2023 Jul 19;24(1):591. doi: 10.1186/s12891-023-06731-0. BMC Musculoskelet Disord. 2023. PMID: 37468856 Free PMC article.
-
Efficacy of internal fixation with mini plate and internal fixation with hollow screw for Regan-Morrey type II and III ulna coronoid fractures.BMC Musculoskelet Disord. 2018 Jun 19;19(1):194. doi: 10.1186/s12891-018-2117-4. BMC Musculoskelet Disord. 2018. PMID: 29921248 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical