Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2015 Oct;35(10):2246-55.
doi: 10.1111/liv.12808. Epub 2015 Feb 26.

Accuracy of transient elastography in assessing liver fibrosis in chronic viral hepatitis: A multicentre, retrospective study

Affiliations
Multicenter Study

Accuracy of transient elastography in assessing liver fibrosis in chronic viral hepatitis: A multicentre, retrospective study

Yeon Seok Seo et al. Liver Int. 2015 Oct.

Abstract

Background/aims: Transient elastography (TE) has become an alternative to liver biopsy (LB). This study investigated the diagnostic performance of liver stiffness (LS) measurement using TE in Korean patients with chronic hepatitis B and C (CHB and CHC).

Methods: From April 2006 to June 2014, 916 patients (567 CHB and 349 CHC) who underwent LB and TE at 15 centres were analyzed. The Batts and Ludwig scoring system was used for histologic assessment. Aspartate aminotransferase (AST)-to-platelet ratio indexes (APRI) were calculated. Area under the receiver operating characteristic curve (AUROC) was used.

Results: The median age, LS value, and APRI score were 45 years, 8.8 kPa, and 0.61, respectively, in CHB patients vs. 51 years, 6.8 kPa and 0.55, respectively, in CHC patients. TE was significantly superior to APRI in CHB patients (AUROC 0.774 vs. 0.72 for ≥F2, 0.849 vs. 0.812 for ≥F3, and 0.902 vs. 0.707 for F4, respectively; all P < 0.05). Furthermore, TE was significantly superior for predicting ≥ F3 stage (AUROC 0.865 vs. 0.840, P = 0.009) whereas it was similar for predicting ≥ F2 and F4 stage (AUROC 0.822 vs. 0.796; 0.910 vs. 0.884; all P > 0.05) in CHC patients. In CHB patients, optimal cut-off LS values were 7.8 kPa for ≥F2, 8.2 kPa for ≥ F3, and 11.6 kPa for F4, vs. 6.8 kPa, 8.6 kPa, and 14.5 kPa, respectively, in CHC patients.

Conclusions: TE can accurately assess the degree of liver fibrosis in Korean patients with CVH. TE was superior to APRI for predicting each fibrosis stage.

Keywords: Fibroscan; Transient elastography; chronic liver disease; cirrhosis; liver fibrosis; liver stiffness; performance.

PubMed Disclaimer

Comment in

Similar articles

Cited by

Publication types

LinkOut - more resources