Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Mar;35(2):179-85.
doi: 10.1111/opo.12199. Epub 2015 Feb 12.

Agreement among optometrists and ophthalmologists in estimating limbal anterior chamber depth using the van Herick method

Affiliations
Free article

Agreement among optometrists and ophthalmologists in estimating limbal anterior chamber depth using the van Herick method

Anish Jindal et al. Ophthalmic Physiol Opt. 2015 Mar.
Free article

Abstract

Purpose: To evaluate the inter-observer agreement for measuring limbal anterior chamber depth (LACD) using the van Herick test in community optometrists, glaucoma specialist optometrists and ophthalmologists.

Methods: The study was divided into two phases. In the first phase, a random sample of 100 UK community optometrists were given an opportunity to select and grade eight digital slit-lamp images of anterior chamber angles using the original van Herick 4 point grading scale. The images were included in a clinical decision making study using computerised virtual case vignettes. In the second phase, hospital-based glaucoma specialist optometrists and glaucoma sub-specialist ophthalmologists graded the LACD of the right eye using a 7-point % grading scale in 57 consecutively presenting patients with suspect glaucoma. Inter-observer agreement was assessed using linearly weighted kappa (κw ).

Results: Inter-observer agreement for community optometrists was moderate, with a mean κw for grading photographic images of 0.50 (95% confidence interval (CI) 0.43-0.57). Overall, ninety-two percent of observations were within one grade of the actual grade, although grading of narrow angles was associated with a 13% false negative error rate (based on a ≤ grade 2 threshold). For Phase 2 of the study, pairwise comparisons between optometrists and ophthalmologists showed that agreement was moderate to substantial (mean κw = 0.54-0.65) with a false negative rate of 1.9% (based on a ≤ 25% threshold). Grading accuracy of specialist optometrists and ophthalmologists were equivalent.

Conclusions: In summary, the present study found that community optometrists showed moderate inter-observer agreement for grading LACD. Glaucoma specialist optometrists showed moderate to substantial agreement with weighted kappa values that were equivalent to sub-specialist ophthalmologists. The augmented 7-point % grading scale is intuitive and potentially offers greater accuracy for grading narrow angles than the traditional 4-point scale for grading LACD.

Keywords: angle closure; inter-observer agreement; van Herick test.