Reference Ranges in [(99m)Tc]Mercaptoacetyltriglycerine Renography: Comparison of a Semi-automated (Xeleris, GE) and Manual (Picker, Odyssey) Processing Software
- PMID: 25693723
- DOI: 10.1007/s11307-014-0813-5
Reference Ranges in [(99m)Tc]Mercaptoacetyltriglycerine Renography: Comparison of a Semi-automated (Xeleris, GE) and Manual (Picker, Odyssey) Processing Software
Abstract
Purpose: The purpose of the study was to define reference ranges for quantitative parameters in [(99m)Tc]mercaptoacetyltriglycerine ([(99m)Tc]MAG3) renography to assist interpretation in a semi-automated (Xeleris, GE) compared to a manual (Picker, Odyssey) software package.
Procedures: Forty-eight subjects approved for renal donation were evaluated with [(99m)Tc]MAG3 renography using both the Xeleris and the Picker software.
Results: Reference ranges for the two software were comparable regarding the relative function of the two kidneys (the split function, SF) and the residual activities (RA). The time to peak whole-kidney activities (T max whole-kidney) was more dependent on the type of software. Using Bland-Altman limits, we found good and acceptable agreement between the two methods.
Conclusions: We found good correlation between renography results using the Xeleris and Picker software packages. However, software-specific reference ranges are needed.
Keywords: ROI; Reference range; Tc-99m-MAG3 renography.
Similar articles
-
The accuracy of quantitative parameters in (99m) Tc-MAG3 dynamic renography: a national audit based on virtual image data.Clin Physiol Funct Imaging. 2016 Mar;36(2):146-54. doi: 10.1111/cpf.12208. Epub 2014 Oct 28. Clin Physiol Funct Imaging. 2016. PMID: 25348641
-
99mTc-MAG3 renography: normal values for MAG3 clearance and curve parameters, excretory parameters, and residual urine volume.AJR Am J Roentgenol. 2006 Dec;187(6):W610-7. doi: 10.2214/AJR.05.1550. AJR Am J Roentgenol. 2006. PMID: 17114514
-
Influence of hydration status in normal subjects: fractional analysis of parameters of Tc-99m DTPA and Tc-99m MAG3 renography.Ann Nucl Med. 2005 Feb;19(1):1-7. doi: 10.1007/BF02986328. Ann Nucl Med. 2005. PMID: 15770966 Clinical Trial.
-
Consensus report on quality control of quantitative measurements of renal function obtained from the renogram: International Consensus Committee from the Scientific Committee of Radionuclides in Nephrourology.Semin Nucl Med. 1999 Apr;29(2):146-59. doi: 10.1016/s0001-2998(99)80005-1. Semin Nucl Med. 1999. PMID: 10321826 Review.
-
Computer-assisted diagnosis in renal nuclear medicine: rationale, methodology, and interpretative criteria for diuretic renography.Semin Nucl Med. 2014 Mar;44(2):146-58. doi: 10.1053/j.semnuclmed.2013.10.007. Semin Nucl Med. 2014. PMID: 24484751 Free PMC article. Review.