Comparison of long-term safety and efficacy outcomes after drug-eluting and bare-metal stent use across racial groups: Insights from NHLBI Dynamic Registry
- PMID: 25697874
- PMCID: PMC4417363
- DOI: 10.1016/j.ijcard.2015.01.071
Comparison of long-term safety and efficacy outcomes after drug-eluting and bare-metal stent use across racial groups: Insights from NHLBI Dynamic Registry
Abstract
Background: Long-term data on outcomes after percutaneous coronary intervention (PCI) with drug-eluting stent (DES) and bare-metal stent (BMS) across racial groups are limited, and minorities are under-represented in existing clinical trials. Whether DES has better long-term clinical outcomes compared to BMS across racial groups remains to be established. Accordingly, we assessed whether longer-term clinical outcomes are better with DES compared to BMS across racial groups.
Methods: Using the multicenter National Heart, Lung, and Blood Institute (NHLBI)-sponsored Dynamic Registry, 2-year safety (death, MI) and efficacy (repeat revascularization) outcomes of 3326 patients who underwent PCI with DES versus BMS were evaluated.
Results: With propensity-score adjusted analysis, the use of DES, compared to BMS, was associated with a lower risk for death or MI at 2 years for both blacks (adjusted Hazard Ratio (aHR)=0.41, 95% CI 0.25-0.69, p<0.001) and whites (aHR=0.67, 95% CI 0.51-0.90, p=0.007). DES use was associated with a significant 24% lower risk of repeat revascularization in whites (aHR=0.76, 95% CI 0.60-0.97, p=0.03) and with nominal 34% lower risk in blacks (aHR=0.66, 95% CI 0.39-1.13, p=0.13).
Conclusion: The use of DES in PCI was associated with better long-term safety outcomes across racial groups. Compared to BMS, DES was more effective in reducing repeat revascularization in whites and blacks, but this benefit was attenuated after statistical adjustment in blacks. These findings indicate that DES is superior to BMS in all patients regardless of race. Further studies are needed to determine long-term outcomes across racial groups with newer generation stents.
Keywords: Coronary stents; Disparity; Long term outcomes; Race.
Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Figures
References
-
- Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O’Shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE SIRIUS Investigators. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003;349:1315–23. - PubMed
-
- Stone GW, Ellis SG, Cox DA, Hermiller J, O’Shaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Popma JJ, Russell ME TAXUS-IV Investigators. One-year clinical results with the slow-release, polymer-based, paclitaxel-eluting Taxus stent: the TAXUS-IV trial. Circulation. 2004;109:1942–7. - PubMed
-
- Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, Colombo A, Schuler G, Barragan P, Guagliumi G, Molnàr F, Falotico R RAVEL Study Group. Randomized Study with the Sirolimus-Coated Bx Velocity Balloon-Expandable Stent in the Treatment of Patients with de Novo Native Coronary Artery Lesions. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med. 2002;346:1773–80. - PubMed
-
- Greenhalgh J, Hockenhull J, Rao N, Dundar Y, Dickson RC, Bagust A. Drug-eluting stents versus bare metal stents for angina or acute coronary syndromes. Cochrane Database Syst Rev. 2010;5:CD004587. - PubMed
-
- Kirtane AJ, Gupta A, Iyengar S, Moses JW, Leon MB, Applegate R, Brodie B, Hannan E, Harjai K, Jensen LO, Park SJ, Perry R, Racz M, Saia F, Tu JV, Waksman R, Lansky AJ, Mehran R, Stone GW. Safety and efficacy of drug-eluting and bare metal stents: comprehensive meta-analysis of randomized trials and observational studies. Circulation. 2009;119:3198–3206. - PubMed