Abstract

Microfocused ultrasound (MFU) has been recently developed to meet the ever-growing public demand for achieving significant, noninvasive skin lifting and tightening. MFU can be focused on subcutaneous tissue where the temperature briefly reaches greater than 60°C, producing small (<1 mm(3)) thermal coagulation points to a depth of up to 5 mm within the mid-to-deep reticular layer of the dermis and subdermis. The intervening papillary dermal and epidermal layers of skin remain unaffected. The application of heat at these discrete thermal coagulation points causes collagen fibers in the facial planes such as the superficial musculoaponeurotic system and platysma, as well as the deep reticular dermis, to become denatured, contracting and stimulating de novo collagen. A commercially available device combines MFU with high-resolution ultrasound imaging (MFU-V), which enables visualization of tissue planes to a depth of 8 mm and allows the user to see where the MFU energy will be applied (Ultherapy(®); Ulthera Inc., Mesa, AZ, USA). Using different transducers, MFU-V treatment can be customized to meet the unique physical characteristics of each patient by adjusting energy and focal depth of the emitted ultrasound. By targeting the facial superficial musculoaponeurotic system, noninvasive tightening and lifting of sagging facial and neck skin and improvements in the appearance of wrinkles can be achieved. MFU-V can also improve lines and wrinkles of the décolleté. Treatment protocols for the use of MFU-V continue to be refined, and its use in combination with other rejuvenation techniques has been demonstrated. Brief discomfort that often occurs during treatment can be minimized with oral nonsteroidal anti-inflammatory drugs. Other treatment-related adverse events include transient erythema, edema, and occasional bruising. MFU-V is best suited for patients with mild-to-moderate skin and soft tissue laxity. For older patients with severe skin laxity and marked platysmal banding, surgical treatment should be considered.

Keywords: facial rejuvenation; microfocused ultrasound; skin lifting; skin tightening; ultherapy.

PubMed Disclaimer

Figures

Figure 1
Figure 1
XX-year-old female; one MFU-V treatment to full face and full neck; total treatment lines are XXX; 8 months later. Abbreviation: MFU, microfocused ultrasound.
Figure 2
Figure 2
Customizing treatment depending on laxity severity.

References

    1. Kim YS, Rhim H, Choi MJ, Lim HK, Choi D. High-intensity focused ultrasound therapy: an overview for radiologists. Korean J Radiol. 2008;9:291–302. - PMC - PubMed
    1. Dubinsky TJ, Cuevas C, Dighe MK, Kolokythas O, Hwang JH. High-intensity focused ultrasound: current potential and oncologic applications. AJR Am J Roentgenol. 2008;190:191–199. - PubMed
    1. Sklar LR, El Tal AK, Kerwin LY. Use of transcutaneous ultrasound for lipolysis and skin tightening: a review. Aesthetic Plast Surg. 2014;38(2):429–441. - PubMed
    1. Orsi F, Arnone P, Chen W, Zhang L. High intensity focused ultrasound ablation: a new therapeutic option for solid tumors. J Cancer Res Ther. 2010;6:414–420. - PubMed
    1. Gadsden E, Aguilar MT, Smoller BR, Jewell ML. Evaluation of a novel high-intensity focused ultrasound device for ablating subcutaneous adipose tissue for noninvasive body contouring: safety studies in human volunteers. Aesthet Surg J. 2011;31(4):401–410. - PubMed