Justification and good practice in using handheld portable dental X-ray equipment: a position paper prepared by the European Academy of DentoMaxilloFacial Radiology (EADMFR)

Affiliations

Justification and good practice in using handheld portable dental X-ray equipment: a position paper prepared by the European Academy of DentoMaxilloFacial Radiology (EADMFR)

W E R Berkhout et al. Dentomaxillofac Radiol. 2015.

Abstract

Handheld portable X-ray devices are increasingly used for intraoral radiography. This development introduces new challenges to staff and patient safety, for which new or revised risk assessments must be made and acted upon prior to use. Major issues might be: difficulties in using rectangular collimation with beam aiming devices, more complex matching of exposure settings to the X-ray receptor used (e.g. longer exposure times), movements owing to the units' weight, protection of the operator and third persons, and the use in uncontrolled environments. These problems may result in violation of the "as low as reasonably achievable'', that is, ALARA principle by an increase in (re)exposures compared with the other available intraoral X-ray devices. Hence, the use of handheld portable X-ray devices should be considered only after careful and documented evaluation (which might be performed based on medical physics support), when there is evidence that handheld operation has benefits over traditional modalities and when no new risks to the operators and/or third parties are caused. It is expected that the use of handheld portable X-ray devices will be very exceptional, and for justified situations only. Special attention should be drawn to beam-aiming devices, rectangular collimation, the section of the X-ray receptor, focus-skin distance, and backscatter shielding, and that the unit delivers reproducible dose over the full set of environmental conditions (e.g. battery status and temperature).

Keywords: X-ray; dental; handheld; portable.

PubMed Disclaimer

References

    1. Van Dis ML, Miles DA, Parks ET, Razmus TF. Information yield from a hand-held dental x-ray unit. Oral Surg Oral Med Oral Pathol 1993; 76: 381–5. - PubMed
    1. Essig SL. New York moves to facilitate the use of hand-held X-ray devices. N Y State Dent J 2009; 75: 57. - PubMed
    1. International standard, medical electrical equipment—part 1–3: general requirements for basic safety and essential performance—collateral standard: radiation protection in diagnostic X-ray equipment. IEC 60601-1-3 ed2.1 Consol. with am1. 2013. Geneva, Switzerland: International Electrotechnical Commission.
    1. International standard, medical electrical equipment—part 2–65: particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment. IEC 60601-2-65 ed1.0. 2012. Geneva, Switzerland: International Electrotechnical Commission.
    1. International standard, evaluation and routine testing in medical imaging departments—part 3–4: acceptance tests—imaging performance of dental X-ray equipment. IEC 61223-3-4 ed1.0. 2000. Geneva, Switzerland: International Electrotechnical Commission.

Publication types