. 2014 Nov;19(4):e18748.
doi: 10.5812/traumamon.18748. Epub 2014 Nov 25.

Electrical burn injury: a five-year survey of 682 patients

Affiliations

Electrical burn injury: a five-year survey of 682 patients

Yaser Ghavami et al. Trauma Mon. 2014 Nov.

Abstract

Background: Electrical burn is less prevalent in comparison to other forms of burn injuries, however this type of injury is considered as one of the most devastating due to high morbidity and mortality. Understanding the epidemiologic pattern of electrical burns helps determine the contributing factors leading to this type of injury.

Objectives: Epidemiologic studies on electrical burn are scarce in Iran. This study was conducted to evaluate electrical burn injury at our center.

Materials and methods: Demographic data, etiology, burn percentage and other measures related to electrical burn injury of 682 electrical burn patients treated from 2007 to 2011 were collected and analyzed.

Results: We assessed 682 electrical burn patients (~10.8% of all burn patients); the mean age was 29.4 years and 97.8% were males. The mean hospital stay was 18.5 days and the mean burn extent was 14.43%. Severe morbidities caused 17 (2.5%) deaths. Amputation was performed in 162 cases. The most common amputation site was the fingers (35%). Most victims were workers and employees and 68.5% of electrical burns occurred at their workplace; 72% of electrical burns were due to high voltage electrical current (more than 1000 V). There was a correlation between voltage and amputation (P = 0.001) and also between voltage and fasciotomy (P = 0.033), but there was no correlation between voltage and mortality (P = 0.131).

Conclusions: Electrical burn injuries are still amongst the highest accident-related morbidities and mortalities. Educating the population about the dangers and hazards associated with improper use of electrical devices and instruments is imperative.

Keywords: Complications; Electric Burns; Injury; Morbidity.

PubMed Disclaimer

Figures

Figure 1.
Figure 1.. Amputation Rate and Site in Patients With Electrical Burn Injury. Amputation was performed in 162 cases, but in some cases the location of amputation was more than one site.

References

    1. Nguyen BH, MacKay M, Bailey B, Klassen TP. Epidemiology of electrical and lightning related deaths and injuries among Canadian children and youth. Inj Prev. 2004;10(2):122–4. - PMC - PubMed
    1. Sahin I, Ozturk S, Alhan D, Acikel C, Isik S. Cost analysis of acute burn patients treated in a burn centre: the Gulhane experience. Ann Burns Fire Disasters. 2011;24(1):9–13. - PMC - PubMed
    1. Patil SB, Khare NA, Jaiswal S, Jain A, Chitranshi A, Math M. Changing patterns in electrical burn injuries in a developing country: should prevention programs focus on the rural population? J Burn Care Res. 2010;31(6):931–4. doi: 10.1097/BCR.0b013e3181f93924. - DOI - PubMed
    1. Mohammadi AA, Amini M, Mehrabani D, Kiani Z, Seddigh A. A survey on 30 months electrical burns in Shiraz University of Medical Sciences Burn Hospital. Burns. 2008;34(1):111–3. doi: 10.1016/j.burns.2006.12.007. - DOI - PubMed
    1. Sheikhazadi A, Kiani M, Ghadyani MH. Electrocution-related mortality: a survey of 295 deaths in Tehran, Iran between 2002 and 2006. Am J Forensic Med Pathol. 2010;31(1):42–5. - PubMed

LinkOut - more resources