In vitro degradation behavior and cytocompatibility of biodegradable AZ31 alloy with PEO/HT composite coating
- PMID: 25731092
- DOI: 10.1016/j.colsurfb.2015.02.011
In vitro degradation behavior and cytocompatibility of biodegradable AZ31 alloy with PEO/HT composite coating
Abstract
Biodegradable magnesium-based implants have attracted much attention recently in orthopedic applications because of their good mechanical properties and biocompatibility. However, their rapid degradation in vivo will not only reduce their mechanical strength, but also induce some side effects, such as local alkalization and gas cavity, which may lead to a failure of the implant. In this work, a hydroxyapatite (HA) layer was prepared on plasma electrolytic oxidization (PEO) coating by hydrothermal treatment (HT) to fabricate a PEO/HT composite coating on biodegradable AZ31 alloy. The in vitro degradation behaviors of all samples were evaluated in simulated body fluid (SBF) and their surface cytocompatibility was also investigated by evaluating the adhesion and proliferation of osteoblast cells (MC3T3-E1). The results showed that the HA layer consisted of a dense inner layer and a needle-like outer layer, which successfully sealed the PEO coating. The in vitro degradation tests showed that the PEO/HT composite coating improved the corrosion resistance of AZ31 alloy in SBF, presenting nearly no severe local alkalization and hydrogen evolution. The lasting corrosion resistance of the PEO/HT composite coating may attribute to the new hydroxyapatite formation during the degradation process. Moreover, compared with AZ31 alloy and PEO coating, PEO/HT composite coating was more suitable for cells adhesion and proliferation, indicating improved surface cytocompatibility. The results show that the PEO/HT composite coating is promising as protective coating on biodegradable magnesium-based implants to enhance their corrosion resistance as well as improve their surface cytocompatibility for orthopedic applications.
Keywords: Corrosion resistance; Cytocompatibility; Hydroxyapatite; Magnesium alloy; PEO coating.
Copyright © 2015 Elsevier B.V. All rights reserved.
Similar articles
-
Mussel-inspired functionalization of PEO/PCL composite coating on a biodegradable AZ31 magnesium alloy.Colloids Surf B Biointerfaces. 2016 May 1;141:327-337. doi: 10.1016/j.colsurfb.2016.02.004. Epub 2016 Feb 4. Colloids Surf B Biointerfaces. 2016. PMID: 26874118
-
Hemocompatibility and selective cell fate of polydopamine-assisted heparinized PEO/PLLA composite coating on biodegradable AZ31 alloy.Colloids Surf B Biointerfaces. 2014 Sep 1;121:451-60. doi: 10.1016/j.colsurfb.2014.06.036. Epub 2014 Jun 21. Colloids Surf B Biointerfaces. 2014. PMID: 25009102
-
Preparation and corrosion resistance of magnesium phytic acid/hydroxyapatite composite coatings on biodegradable AZ31 magnesium alloy.J Mater Sci Mater Med. 2017 Jun;28(6):82. doi: 10.1007/s10856-017-5876-9. Epub 2017 Apr 19. J Mater Sci Mater Med. 2017. PMID: 28424946
-
Surface characterization and corrosion behavior of calcium phosphate-base composite layer on titanium and its alloys via plasma electrolytic oxidation: A review paper.Mater Sci Eng C Mater Biol Appl. 2015 Dec 1;57:397-413. doi: 10.1016/j.msec.2015.07.058. Epub 2015 Aug 5. Mater Sci Eng C Mater Biol Appl. 2015. PMID: 26354281 Review.
-
Advances in amelioration of plasma electrolytic oxidation coatings on biodegradable magnesium and alloys.Heliyon. 2024 Jan 11;10(4):e24348. doi: 10.1016/j.heliyon.2024.e24348. eCollection 2024 Feb 29. Heliyon. 2024. PMID: 38434039 Free PMC article. Review.
Cited by
-
The Impact of Pre- and Post-Treatment Processes on Corrosion Resistance of Micro-Arc Oxidation Coatings on Mg Alloys: A Systematic Review.Materials (Basel). 2025 Feb 6;18(3):723. doi: 10.3390/ma18030723. Materials (Basel). 2025. PMID: 39942388 Free PMC article. Review.
-
Corrosion and biocompatibility behaviours of microarc oxidation/phytic acid coated magnesium alloy clips for use in cholecystectomy in a rabbit model.RSC Adv. 2021 Jun 10;11(34):20730-20736. doi: 10.1039/d0ra09275d. eCollection 2021 Jun 9. RSC Adv. 2021. PMID: 35479380 Free PMC article.
-
Effects of Corroded and Non-Corroded Biodegradable Mg and Mg Alloys on Viability, Morphology and Differentiation of MC3T3-E1 Cells Elicited by Direct Cell/Material Interaction.PLoS One. 2016 Jul 26;11(7):e0159879. doi: 10.1371/journal.pone.0159879. eCollection 2016. PLoS One. 2016. PMID: 27459513 Free PMC article.
-
Fabrication of hydroxyapatite coatings on AZ31 Mg alloy by micro-arc oxidation coupled with sol-gel treatment.RSC Adv. 2018 Apr 3;8(22):12368-12375. doi: 10.1039/c7ra10951b. eCollection 2018 Mar 26. RSC Adv. 2018. PMID: 35539426 Free PMC article.
-
Bioactivity Performance of Pure Mg after Plasma Electrolytic Oxidation in Silicate-Based Solutions.Molecules. 2021 Apr 6;26(7):2094. doi: 10.3390/molecules26072094. Molecules. 2021. PMID: 33917454 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources