Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Apr;59(4):448-56.
doi: 10.1111/aas.12497. Epub 2015 Mar 3.

Veno-venous extracorporeal CO2 removal improves pulmonary hemodynamics in a porcine ARDS model

Affiliations
Free article

Veno-venous extracorporeal CO2 removal improves pulmonary hemodynamics in a porcine ARDS model

P Morimont et al. Acta Anaesthesiol Scand. 2015 Apr.
Free article

Abstract

Background: Protective lung ventilation is recommended in patients with acute respiratory distress syndrome (ARDS) to minimize additional injuries to the lung. However, hypercapnic acidosis resulting from ventilation at lower tidal volume enhances pulmonary hypertension and might induce right ventricular (RV) failure. We investigated if extracorporeal veno-venous CO2 removal therapy could have beneficial effects on pulmonary circulation and RV function.

Methods: This study was performed on an experimental model of ARDS obtained in eight anaesthetized pigs connected to a volume-cycled ventilator. A micromanometer-tipped catheter was inserted into the main pulmonary artery and an admittance micromanometer-tipped catheter was inserted into the right ventricle. RV-arterial coupling was derived from RV pressure-volume loops. ARDS was obtained by repeated bronchoalveolar lavage. Protective ventilation was then achieved, and the pigs were connected to a pump-driven extracorporeal membrane oxygenator (PALP, Maquet, Germany) in order to achieve CO2 removal.

Results: ARDS induced severe hypercapnic acidosis. Systolic pulmonary artery pressure significantly increased from 29.6±1.8 to 43.9±2.0 mmHg (P<0.001). After the PALP was started, acidosis was corrected and normocarbia was maintained despite protective ventilation. Pulmonary artery pressure significantly decreased to 31.6±3.2 mmHg (P<0.001) and RV-arterial coupling significantly improved (RV-arterial coupling index=1.03±0.33 vs. 0.55±0.41, P<0.05).

Conclusion: Veno-venous CO2 removal therapy enabled protective ventilation while maintaining normocarbia during ARDS. CO2 removal decreased pulmonary hypertension and improved RV function. This technique may be an effective lung- and RV-protective adjunct to mechanical ventilation.

PubMed Disclaimer

Publication types