Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Sep;41(5):304-9.
doi: 10.1097/ICL.0000000000000124.

Migration of Cosmetic Products into the Tear Film

Affiliations

Migration of Cosmetic Products into the Tear Film

Alison Ng et al. Eye Contact Lens. 2015 Sep.

Abstract

Purpose: To examine, record, and quantify the migration of a conventional eye cosmetic pencil when applied to periocular skin in two different locations: behind the lash line (ELI) and along the periocular skin (ELO).

Methods: This was a pilot study (prospective, randomized crossover design) involving two visits on separate days. Three female subjects were randomly assigned one of two eyeliner application conditions: ELI (inside the lash line) or ELO (anterior to the lash line). Pencil eyeliner ("Glimmerstick" in Graphite; Avon, Northampton, United Kingdom) was applied to the subject's upper and lower right eyelid by the examiner. Slitlamp video recording of glitter particles suspended within the tear film was conducted for 30 sec on 10 occasions up to 2 hr post-eyeliner application. The number of glitter particles suspended in the tear film, analyzed using ImageJ software, is reported.

Results: The migration of the glitter particles occurred more readily in ELI application, with maximum contamination of the tear film achieved 5 to 10 min post-application. The migration of eyeliner following ELO application was comparatively slower and reduced compared with ELI application. The quantity of glitter particles suspended in the tear film varied between subjects; however, 2 hr post-application, contamination of the tear film from pencil eyeliner was negligible.

Conclusions: Pencil eyeliner migrates most readily and maximally contaminates the tear film when applied posterior to the lash line. This has implications for contact lens wearers and patients with dry eye syndrome or sensitive eyes. Eye cosmetic usage for participants involved in anterior eye and contact lens research should be carefully considered in the design of studies.

PubMed Disclaimer

Publication types

LinkOut - more resources