High-performance liquid chromatographic determination of beta-adrenoceptor blocking agents in body fluids
- PMID: 2574057
- DOI: 10.1002/bmc.1130030402
High-performance liquid chromatographic determination of beta-adrenoceptor blocking agents in body fluids
Abstract
Several reports have been published reviewing high-performance liquid chromatographic (HPLC) methods for the determination of beta-adrenoceptor blocking agents (beta-blockers) in biological materials (Flouvat et al., 1981; Mehta, 1983; Marko and Soltés, 1984; Ahnoff et al., 1985; Tkaczyková and Safarík, 1987). Of these, the paper by Mehta (1983) briefly summarizes the interrelationship between physiocochemical properties of beta-blockers with prechromatographic treatment of biological samples, as well as with the HPLC methods used for the determination of 12 beta-adrenoceptor blocking drugs. The work by Ahnoff et al. (1985) concerning the monitoring of cardiovascular drugs also deals with HPLC assays of 18 beta-blockers in plasma. The Appendix to this report presents the great majority of HPLC methods for determining 30 beta-blockers in various body fluids. HPLC methods providing resolution and determination of individual beta-blocker enantiomers have not been included since this topic is being covered by Walle and Walle (1989). The Appendix is just a guide to the methods reviewed for the HPLC determination of parent beta-blockers as well as some of their metabolites co-assayed in various body fluids. It does not include details such as the internal standard, recovery, setting of the detector, limit of determination, etc., given in the individual methods listed. The isolation technique of the drug(s) from the given body fluid represents the main step in the sample work-up procedure. Along with this information, only the type of the HPLC column packing and the detection principle used by each method's developers are given.
Similar articles
-
Aminoglycoside antibiotics--two decades of their HPLC bioanalysis.Biomed Chromatogr. 1999 Feb;13(1):3-10. doi: 10.1002/(SICI)1099-0801(199902)13:1<3::AID-BMC811>3.0.CO;2-T. Biomed Chromatogr. 1999. PMID: 10191936
-
Development, validation and analytical error function of two chromatographic methods with fluorimetric detection for the determination of bisoprolol and metoprolol in human plasma.Biomed Chromatogr. 2002 Dec;16(8):517-22. doi: 10.1002/bmc.195. Biomed Chromatogr. 2002. PMID: 12474215
-
High-performance liquid chromatographic determination of the enantiomers of beta-adrenoceptor blocking agents in biological fluids. II. Studies with atenolol.J Chromatogr. 1989 Apr 14;489(2):438-45. doi: 10.1016/s0378-4347(00)82927-8. J Chromatogr. 1989. PMID: 2568994 No abstract available.
-
Detection and quantitation of β-blockers in plasma and urine.Bioanalysis. 2010 Feb;2(2):263-76. doi: 10.4155/bio.09.184. Bioanalysis. 2010. PMID: 21083309 Review.
-
Antibiotic monitoring in body fluids.J Chromatogr. 1985 May 10;340:361-400. doi: 10.1016/0378-4347(85)80202-4. J Chromatogr. 1985. PMID: 3894402 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources