Influence of material surface on the scanning error of a powder-free 3D measuring system
- PMID: 25743568
- DOI: 10.1007/s00784-015-1440-5
Influence of material surface on the scanning error of a powder-free 3D measuring system
Abstract
Objectives: This study aims to evaluate the accuracy of a powder-free three-dimensional (3D) measuring system (CEREC Omnicam, Sirona), when scanning the surface of a material at different angles. Additionally, the influence of water was investigated.
Materials and methods: Nine different materials were combined with human tooth surface (enamel) to create n = 27 specimens. These materials were: Controls (InCoris TZI and Cerec Guide Bloc), ceramics (Vitablocs® Mark II and IPS Empress CAD), metals (gold and amalgam) and composites (Tetric Ceram, Filtek Supreme A2B and A2E). The highly polished samples were scanned at different angles with and without water. The 216 scans were then analyzed and descriptive statistics were obtained.
Results: The height difference between the tooth and material surfaces, as measured with the 3D scans, ranged from 0.83 μm (±2.58 μm) to -14.79 μm (±3.45 μm), while the scan noise on the materials was between 3.23 μm (±0.79 μm) and 14.24 μm (±6.79 μm) without considering the control groups. Depending on the thickness of the water film, measurement errors in the order of 300-1,600 μm could be observed.
Conclusions: The inaccuracies between the tooth and material surfaces, as well as the scan noise for the materials, were within the range of error for measurements used for conventional impressions and are therefore negligible. The presence of water, however, greatly affects the scan.
Clinical relevance: The tested powder-free 3D measuring system can safely be used to scan different material surfaces without the prior application of a powder, although drying of the surface prior to scanning is highly advisable.
Keywords: Accuracy; CAD/CAM; Digital workflow; Impression technique; Intraoral scanning.
Similar articles
-
[Comparative analysis of 3D data accuracy of single tooth and full dental arch captured by different intraoral and laboratory digital impression systems].Stomatologiia (Mosk). 2016;95(4):65-70. doi: 10.17116/stomat201695465-70. Stomatologiia (Mosk). 2016. PMID: 27636766 Russian.
-
Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner.Am J Orthod Dentofacial Orthop. 2013 Sep;144(3):471-8. doi: 10.1016/j.ajodo.2013.04.017. Am J Orthod Dentofacial Orthop. 2013. PMID: 23992820
-
3D and 2D marginal fit of pressed and CAD/CAM lithium disilicate crowns made from digital and conventional impressions.J Prosthodont. 2014 Dec;23(8):610-7. doi: 10.1111/jopr.12180. Epub 2014 Jul 3. J Prosthodont. 2014. PMID: 24995593
-
Accuracy of Intraoral Digital Impressions for Whole Upper Jaws, Including Full Dentitions and Palatal Soft Tissues.PLoS One. 2016 Jul 6;11(7):e0158800. doi: 10.1371/journal.pone.0158800. eCollection 2016. PLoS One. 2016. PMID: 27383409 Free PMC article.
-
Translucency of ceramic materials for CEREC CAD/CAM system.J Esthet Restor Dent. 2014 Jul-Aug;26(4):224-31. doi: 10.1111/jerd.12105. Epub 2014 Jun 29. J Esthet Restor Dent. 2014. PMID: 24974858
Cited by
-
An Evaluation of the Accuracy of Digital Models-An In Vitro Study.Dent J (Basel). 2024 Sep 29;12(10):313. doi: 10.3390/dj12100313. Dent J (Basel). 2024. PMID: 39452441 Free PMC article.
-
Innovation by Computer-Aided Design/Computer-Aided Manufacturing Technology: A Look at Infection Prevention in Dental Settings.Biomed Res Int. 2019 Aug 6;2019:6092018. doi: 10.1155/2019/6092018. eCollection 2019. Biomed Res Int. 2019. PMID: 31467901 Free PMC article. Review.
-
Accuracy of intraoral and extraoral digital data acquisition for dental restorations.J Appl Oral Sci. 2016 Jan-Feb;24(1):85-94. doi: 10.1590/1678-775720150266. J Appl Oral Sci. 2016. PMID: 27008261 Free PMC article.
-
A novel method for testing accuracy of bite registration using intraoral scanners.Korean J Orthod. 2023 Jul 25;53(4):254-263. doi: 10.4041/kjod22.199. Epub 2023 Jun 23. Korean J Orthod. 2023. PMID: 37497582 Free PMC article.
-
Accuracy on Scanned Images of Full Arch Models with Orthodontic Brackets by Various Intraoral Scanners in the Presence of Artificial Saliva.Biomed Res Int. 2020 Feb 27;2020:2920804. doi: 10.1155/2020/2920804. eCollection 2020. Biomed Res Int. 2020. PMID: 32185200 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous