A systematic review of ICD complications in randomised controlled trials versus registries: is our 'real-world' data an underestimation?

Affiliations
Review

A systematic review of ICD complications in randomised controlled trials versus registries: is our 'real-world' data an underestimation?

Vivienne A Ezzat et al. Open Heart. .

Abstract

Implantable cardioverter defibrillator (ICD) implantation carries a significant risk of complications, however published estimates appear inconsistent. We aimed to present a contemporary systematic review using meta-analysis methods of ICD complications in randomised controlled trials (RCTs) and compare it to recent data from the largest international ICD registry, the US National Cardiovascular Data Registry (NCDR). PubMed was searched for any RCTs involving ICD implantation published 1999-2013; 18 were identified for analysis including 6433 patients, mean follow-up 3 months-5.6 years. Exclusion criteria were studies of children, hypertrophic cardiomyopathy, congenital heart disease, resynchronisation therapy and generator changes. Total pooled complication rate from the RCTs (excluding inappropriate shocks) was 9.1%, including displacement 3.1%, pneumothorax 1.1% and haematoma 1.2%. Infection rate was 1.5%.There were no predictors of complications but longer follow-up showed a trend to higher complication rates (p=0.07). In contrast, data from the NCDR ICD, reporting on 356 515 implants (2006-2010) showed a statistically significant threefold lower total major complication rate of 3.08% with lead displacement 1.02%, haematoma 0.86% and pneumothorax 0.44%. The overall ICD complication rate in our meta-analysis is 9.1% over 16 months. The ICD complication reported in the NCDR ICD registry is significantly lower despite a similar population. This may reflect under-reporting of complications in registries. Reporting of ICD complications in RCTs and registries is very variable and there is a need to standardise classification of complications internationally.

Keywords: QUALITY OF CARE AND OUTCOMES.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Complication rates in randomised controlled trials (RCTs) compared to registry.

References

    1. http://guidance.nice.org.uk/TA95.
    1. Al-Khatib SM, Hellkamp A, Bardy GH et al. . Survival of patients receiving a primary prevention implantable cardioverter-defibrillator in clinical practice vs clinical trials. JAMA 2013;309:55–62. 10.1001/jama.2012.157182 - DOI - PMC - PubMed
    1. van Rees JB, de Bie MK, Thijssen J et al. . Implantation-related complications of implantable cardioverter-defibrillators and cardiac resynchronization therapy devices: a systematic review of randomized clinical trials. J Am Coll Cardiol 2011;58:995–1000. 10.1016/j.jacc.2011.06.007 - DOI - PubMed
    1. Dodson JA, Reynolds MR, Bao H et al. . Developing a risk model for in-hospital adverse events following implantable cardioverter-defibrillator implantation: a report from the NCDR (National Cardiovascular Data Registry). J Am Coll Cardiol 2014;63:788–96. 10.1016/j.jacc.2013.09.079 - DOI - PMC - PubMed
    1. Freeman JV, Wang Y, Curtis JP et al. . Physician procedure volume and complications of cardioverter-defibrillator implantation. Circulation 2012;125:57–64. 10.1161/CIRCULATIONAHA.111.046995 - DOI - PubMed

Publication types