. 2014;24(4):259-65.
doi: 10.1615/jlongtermeffmedimplants.2014010562.

Role of macrophages in the biological reaction to wear debris from joint replacements

Affiliations

Role of macrophages in the biological reaction to wear debris from joint replacements

Christophe Nich et al. J Long Term Eff Med Implants. 2014.

Abstract

Normal usage of total joint replacements results in the production of wear debris and other byproducts. In particular, polyethylene particles are heavily involved in the stimulation of local and systemic biological reactions resulting in chronic inflammation, periprosthetic bone resorption (osteolysis), and, eventually, implant loosening. As sentinels of the innate immune system, cells of the monocyte/macrophage lineage initiate the inflammatory cascade that leads to osteolysis. The biological processes involved are complex, based on the unique properties of the monocytes/macrophages, including sensing, chemotaxis, phagocytosis, and adaptive stimulation. The interaction with wear debris triggers the release of pro-inflammatory factors, such as TNF-α, IL-1, and others, pro-osteoclastic factors such as RANKL, and chemokines, such as MCP-1 and MIP-1, all being crucial to the recruitment, migration, differentiation, and ultimately activation of bone resorbing osteoclasts. In parallel, other distinct macrophage populations inhibit inflammation and mitigate its consequences on the bone-implant interface. Here, the role of the monocyte/macrophage cell lineage in the initiation and maintenance of the host inflammatory response to wear debris and subsequent periprosthetic osteolysis is presented.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Lübbeke A, Garavaglia G, Barea C, Stern R, Peter R, Hoffmeyer P. Influence of patient activity on femoral osteolysis at five and ten years following hybrid total hip replacement. J Bone Joint Surg Br. 2011 Apr;93(4):456–463. - PubMed
    1. Devane PA, Bourne RB, Rorabeck CH, MacDonald S, Robinson EJ. Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application. Clin Orthop Relat Res. 1995 Oct;319:317–326. - PubMed
    1. Berger RA, Jacobs JJ, Quigley LR, Rosenberg AG, Galante JO. Primary cementless acetabular reconstruction in patients younger than 50 years old. 7- to 11-year results. Clin Orthop Relat Res. 1997 Nov;344:216–226. - PubMed
    1. Willert HG, Semlitsch M. Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res. 1977 Mar;11(2):157–164. - PubMed
    1. Schmalzried TP, Jasty M, Harris WH. Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg Am. 1992 Jul;74(6):849–863. - PubMed

Publication types