A new design method for extracorporeal high-intensity focused ultrasound annular array
- PMID: 25752772
- DOI: 10.1007/s11517-015-1273-z
A new design method for extracorporeal high-intensity focused ultrasound annular array
Abstract
Considering the damage to normal tissues during the high-intensity focused ultrasound ablation of the tumor is important. The purpose of this work was to design the annular array under the considerations of preventing the skin burn and damage to normal tissues behind the tumor target. Based on the Rayleigh-Summerfield pressure integral, the numerical acoustic intensity field of a spherical bowl annular array with a diameter of 12 cm and a radius of curvature of 12 cm was obtained by using the MATLAB software. An absorbed intensity ratio of the normal tissue to target was proposed to define the allowable grating lobe for determining the focusing range. The analytic results showed that for the treatment of uterine fibroids, the focusing range increased as the number of the element increased from 9 to 22 and the 14-ring array at the operating frequency of 0.8, 0.9 or 1.0 MHz had a focusing range larger than 5.5 cm when the range was only 4 cm at 1.2 MHz. For the treatment of medullary carcinoma and scirrhous carcinoma in breast, the focusing range of the 0.9-MHz, 14-ring annular array was 8-12 and 8-14 cm, respectively.
Similar articles
-
Simulation study of the effects of near- and far-field heating during focused ultrasound uterine fibroid ablation using an electronically focused phased array: A theoretical analysis of patient safety.Med Phys. 2014 Jul;41(7):072902. doi: 10.1118/1.4883777. Med Phys. 2014. PMID: 24989412
-
Feasibility of magnetic resonance imaging-guided high intensity focused ultrasound therapy for ablating uterine fibroids in patients with bowel lies anterior to uterus.Eur J Radiol. 2010 Feb;73(2):396-403. doi: 10.1016/j.ejrad.2008.11.002. Epub 2008 Dec 23. Eur J Radiol. 2010. PMID: 19108974 Clinical Trial.
-
Improved intercostal HIFU ablation using a phased array transducer based on Fermat's spiral and Voronoi tessellation: A numerical evaluation.Med Phys. 2017 Mar;44(3):1071-1088. doi: 10.1002/mp.12082. Epub 2017 Feb 13. Med Phys. 2017. PMID: 28058731
-
Sonographically guided high-intensity focused ultrasound for the management of uterine fibroids.J Ultrasound Med. 2013 Aug;32(8):1353-8. doi: 10.7863/ultra.32.8.1353. J Ultrasound Med. 2013. PMID: 23887944 Review.
-
Clinical applications of high-intensity focused ultrasound.Hong Kong Med J. 2016 Aug;22(4):382-92. doi: 10.12809/hkmj154755. Epub 2016 Jul 6. Hong Kong Med J. 2016. PMID: 27380753 Review.