Applying terahertz technology for nondestructive detection of crack initiation in a film-coated layer on a swelling tablet
- PMID: 25755992
- PMCID: PMC4167182
- DOI: 10.1016/j.rinphs.2012.04.001
Applying terahertz technology for nondestructive detection of crack initiation in a film-coated layer on a swelling tablet
Abstract
Here, we describe a nondestructive approach using terahertz wave to detect crack initiation in a film-coated layer on a drug tablet. During scale-up and scale-down of the film coating process, differences in film density and gaps between the film-coated layer and the uncoated tablet were generated due to differences in film coating process parameters, such as the tablet-filling rate in the coating machine, spray pressure, and gas-liquid ratio etc. Tablets using the PEO/PEG formulation were employed as uncoated tablets. We found that heat and humidity caused tablets to swell, thereby breaking the film-coated layer. Using our novel approach with terahertz wave nondestructively detect film surface density (FSD) and interface density differences (IDDs) between the film-coated layer and an uncoated tablet. We also found that a reduced FSD and IDD between the film-coated layer and uncoated tablet increased the risk of crack initiation in the film-coated layer, thereby enabling us to nondestructively predict initiation of cracks in the film-coated layer. Using this method, crack initiation can be nondestructively assessed in swelling tablets after the film coating process without conducting accelerated stability tests, and film coating process parameters during scale-up and scale-down studies can be appropriately established.
Keywords: Coating; Process analytical technology; Quality by design; Spectroscopy; Swelling; Terahertz.
Figures
References
-
- Alcaná M., León J., Ropero J., Blanco M., Romanach R.J. Analysis of low content drug tablets by transmission near infrared spectroscopy: selection of calibration ranges according to multivariate detection and quantitation limits of PLS models. Journal of Pharmaceutical Sciences. 2008;97:5318–5327. - PubMed
-
- Cogdill R.P., Forcht R.N., Shen Y., Taday P.F., Creekmore J.R., Anderson C.A., Drennen J.K., III Comparison of terahertz pulse imaging and near-infrared spectroscopy for rapid, nondestructive analysis of tablet coating thickness and uniformity. The Journal of Pharmaceutical Innovation. 2007;2:29–36.
-
- FDA. Guidance for industry, PAT—a framework for innovative pharmaceutical development. Manufacturing, and quality assurance, pharmaceutical CGMPs; 2004.
-
- FDA. Guidance for industry, process validation: general principles and practices; 2008.
-
- FDA/ICH. Guidance for industry. Q8 pharmaceutical development; 2006a.