Impact of injected dose and acquisition time on a normal database by use of 3D-SSP in SPECT images: quantitative simulation studies
- PMID: 25758210
- DOI: 10.1007/s12194-015-0311-8
Impact of injected dose and acquisition time on a normal database by use of 3D-SSP in SPECT images: quantitative simulation studies
Abstract
The present study aimed to validate the accuracy of normal databases (NDBs) with respect to variable injected doses and acquisition times by use of three-dimensional stereotactic surface projections (3D-SSP) in N-isopropyl-p-[123I]-iodoamphetamine (I-123-IMP) brain perfusion images. We constructed NDBs based on brain SPECT images obtained from 29 healthy volunteers. Each NDB was rebuilt under simulated unique conditions by use of dynamic acquisition datasets and comprised injected doses (222, 167, and 111 MBq) and acquisition times (30, 20, and 15 min). We selected seven of 29 datasets derived from the volunteers to simulate patients' data (PD). The simulated PD were designed to include regions of hypoperfusion. The study comprised protocol A (same conditions for PD and NDB) and protocol B (mismatched conditions for PD and NDB). We used 3D-SSP to compare with the Z score and detection error. The average Z scores were decreased significantly in protocol A [PD (High)-NDB (High) vs. PD (Low)-NDB (Low); PD (30 m)-NDB (30 m) vs. PD (15 m)-NDB (15 m) and PD (20 m)-NDB (20 m)].The average Z scores of PD (High) and PD (Medium) with NDB (High) did not differ significantly in protocol B, whereas all others were decreased significantly. The error of detection increased 6.65 % (protocol A) and 32.05 % (protocol B). The Z scores were specific to the injected dose and acquisition time used in 3D-SSP studies, and the calculated Z scores were affected by mismatched injected doses and acquisition times between PD and selected NDBs.
Similar articles
-
Does applying resolution recovery to normal databases confer an advantage over conventional 3D-stereotactic surface projection techniques?Radiol Phys Technol. 2017 Jun;10(2):240-248. doi: 10.1007/s12194-017-0391-8. Epub 2017 Feb 4. Radiol Phys Technol. 2017. PMID: 28161808
-
Evaluation of a novel normal database with matched SPECT systems and optimal pre-filter parameters for 3D-SSP.Ann Nucl Med. 2012 Jan;26(1):16-25. doi: 10.1007/s12149-011-0534-7. Epub 2011 Sep 10. Ann Nucl Med. 2012. PMID: 21909693
-
[Availability of normal database by single photon emission computed tomography system with use of 3 dimensional-stereotactic surface projections].Nihon Hoshasen Gijutsu Gakkai Zasshi. 2012;68(12):1608-16. doi: 10.6009/jjrt.2012_jsrt_68.12.1608. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2012. PMID: 23257590 Japanese.
-
[Neurological diseases and SPECT--analysis using easy Z-score imaging system (eZIS)].Brain Nerve. 2007 May;59(5):487-93. Brain Nerve. 2007. PMID: 17533974 Review. Japanese.
-
Stereotactic statistical imaging analysis of the brain using the easy Z-score imaging system for sharing a normal database.Radiat Med. 2006 Aug;24(7):545-52. doi: 10.1007/s11604-006-0056-8. Radiat Med. 2006. PMID: 17058152 Review.
Cited by
-
The utility of customised tissue probability maps and templates for patients with idiopathic normal pressure hydrocephalus: a computational anatomy toolbox (CAT12) study.Fluids Barriers CNS. 2024 Dec 30;21(1):108. doi: 10.1186/s12987-024-00611-y. Fluids Barriers CNS. 2024. PMID: 39736638 Free PMC article.