Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2015 May;94(5):682-9.
doi: 10.1177/0022034515576195. Epub 2015 Mar 10.

Supplemental vibrational force during orthodontic alignment: a randomized trial

Affiliations
Randomized Controlled Trial

Supplemental vibrational force during orthodontic alignment: a randomized trial

N R Woodhouse et al. J Dent Res. 2015 May.

Abstract

This prospective 3-arm parallel-group randomized clinical trial investigated the effect of supplemental vibrational force on rate of orthodontic tooth alignment with fixed appliances. Eighty-one subjects (40 males, 41 females; mean age, 14.1 y) undergoing first premolar extraction-based fixed appliance treatment were randomly allocated to treatment supplemented with daily use (20 min) of a removable intraoral vibrational device (AcceleDent; OrthoAccel Technologies Inc.; n = 29), an identical nonfunctional (sham) device (n = 25), or fixed appliances only (n = 27). Mandibular study casts were taken at baseline (treatment start: placement of 0.014-in. nickel-titanium arch wire), initial alignment (0.018-in. nickel-titanium arch wire), and final alignment (0.019 x 0.025-in. stainless steel arch wire). Overall mean irregularity index in the mandibular arch at baseline was 8.5 ± 3.8 mm (95% CI, 7.6 to 9.3) with no significant difference between groups (P = 0.73). For the total sample, mean irregularity index at initial alignment was 2.7 ± 2.8 mm (95% CI, 2.2 to 3.4) with no significant difference between groups (P = 0.40). Mean time from baseline to initial alignment was 59 ± 25 d (95% CI, 54.5 to 65.6); from initial to final alignment, 150 ± 62.5 d (95% CI, 136 to 165); and baseline to final alignment, 209 ± 65 d (95% CI, 195 to 224). Kaplan-Meier analysis demonstrated that patterns of alignment were not significantly different among the 3 groups (P = 0.66). Multivariate linear regression for initial and overall alignment rates using initial irregularity index as the covariate showed no significant differences among groups. The most important influence on both initial and overall rates of alignment was initial irregularity (P = 0.1 × 10(-4)). This prospective randomized clinical trial found no evidence that supplemental vibrational force can significantly increase the rate of initial tooth movement or reduce the amount of time required to achieve final alignment when used in conjunction with a preadjusted edgewise fixed appliance (ClinicalTrials.gov NCT02314975).

Keywords: AcceleDent; corrective orthodontics; orthodontic appliances; prospective investigation; tooth movement; vibration.

PubMed Disclaimer

Publication types

Associated data

LinkOut - more resources