Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2015 Aug;104(8):e337-43.
doi: 10.1111/apa.12998. Epub 2015 Apr 13.

High-flow nasal cannulae are associated with increased diaphragm activation compared with nasal continuous positive airway pressure in preterm infants

Affiliations
Randomized Controlled Trial

High-flow nasal cannulae are associated with increased diaphragm activation compared with nasal continuous positive airway pressure in preterm infants

Nehad Nasef et al. Acta Paediatr. 2015 Aug.

Abstract

Aim: High-flow nasal cannulae (HFNC) are increasingly used for respiratory management of preterm infants. However, their ability to provide support compared to nasal continuous positive airway pressure (CPAP) has been questioned. We compared the effect of HFNC versus nasal CPAP on diaphragm electrical activity (EAdi) in preterm infants.

Methods: Preterm infants ≤1500 g were randomised in a crossover design to receive 2 hours of either Infant Flow(®) CPAP (IF-CPAP) at 5-6 cmH2 O or HFNC with the flow rate adjusted to achieve an equivalent pharyngeal pressure. A feeding catheter with miniaturised sensors was inserted for continuous EAdi measurement.

Results: The study comprised ten infants. Physiologic parameters and oxygen requirements were not different between the two modes. However, seven infants demonstrated a higher EAdi peak and six showed a higher EAdi tonic on HFNC, even though the mean group data showed no difference between HFNC and IF-CPAP. Neural inspiratory time was significantly longer with HFNC than IF-CPAP (0.55 ± 0.11 versus 0.48 ± 0.06 seconds, p = 0.018).

Conclusion: In this cohort of preterm infants, the majority exhibited greater diaphragm activation, as assessed by neural breathing patterns, when supported with HFNC than IF-CPAP, suggesting that nasal CPAP may provide more effective respiratory support.

Keywords: Continuous positive airway pressure; Diaphragm; Electromyography; High-flow nasal cannulae; Infants.

PubMed Disclaimer

Publication types

LinkOut - more resources