Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Jul;13(3):478-83.
doi: 10.2450/2015.0198-14. Epub 2015 Feb 2.

Safety and efficacy of granulocyte colony-stimulating factor biosimilars in engraftment after autologous stem cell transplantation for haematological malignancies: a 4-year, single institute experience with different conditioning regimens

Affiliations

Safety and efficacy of granulocyte colony-stimulating factor biosimilars in engraftment after autologous stem cell transplantation for haematological malignancies: a 4-year, single institute experience with different conditioning regimens

Simona Bassi et al. Blood Transfus. 2015 Jul.

Abstract

Background: Filgrastim biosimilars have recently been introduced into clinical practice. To date biosimilars have demonstrated comparable efficacy and safety as the originator in chemotherapy-induced neutropenia. Published experience in engraftment after autologous stem cell transplantation (ASCT) is limited and concerns relatively few patients.

Materials and methods: With the aim of assessing the efficacy and the safety of filgrastim biosimilars in post-ASCT bone marrow recovery, we conducted a single institution, retrospective study in 56 lymphoma and myeloma patients who received filgrastim biosimilars (Tevagrastim(®) and Zarzio(®)) at standard doses from day 5. We compared our results with recently published data on the originator. A cost analysis of each biosimilar was performed.

Results: Neutrophil counts recovered in 55 patients. The median number of filgrastim biosimilar vials injected was seven per patient. The median time to neutrophil and platelet recovery was 10 and 12 days, respectively. Twenty-six patients had febrile neutropenia, in half of whom the agent involved was identified. In the cost analysis, the use of Tevagrastim(®) and Zarzio(®) was associated with cost reductions of 56% and of 86%, respectively.

Discussion: Despite differences in CD34+ cell counts and time of starting filgrastim, our results in terms of time to engraftment and median number of vials injected are similar to published data. Comparing our results by single conditioning regimen to recent literature data, the time to engraftment and duration of hospitalisation were equivalent. Significant differences were observed in the incidence of febrile neutropenia, perhaps due to different preventive and prophylactic protocols for infections. Although prospective studies should be performed to confirm our results, filgrastim biosimilars were found to be effective and safe in engraftment after ASCT.

PubMed Disclaimer

References

    1. Aapro MS, Cameron DA, Pettengell R, et al. EORTC guidelines for the use of granulocyte-colony stimulating factor to reduce the incidence of chemotherapy-induced febrile neutropenia in adult patients with lymphomas and solid tumours. Eur J Cancer. 2006;42:2433–53. - PubMed
    1. Smith TJ, Khatcheressian J, Lyman GH, et al. 2006 update of recommendations for the use of white blood cell growth factors: an evidence-based clinical practice guideline. J Clin Oncol. 2006;24:3187–205. - PubMed
    1. Sorgel F, Lerch H, Lauber T. Physicochemical and biologic comparability of a biosimilar granulocyte colony-stimulating factor with its reference product. Biodrugs. 2010;24:347–57. - PubMed
    1. Niederwieser D, Schmitz S. Biosimilar agents in oncology/hematology: from approval to practice. Eur J Hematol. 2011;86:277–88. - PMC - PubMed
    1. European Medicines Agency. Assessment Report for Ratiograstim. [Accessed on 05/07/2014]. Available at: http://www.ema.europa.eu/docs/en_GB/document_library/EPAR_-_Public_asses....

MeSH terms