Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015:14.
doi: 10.2310/7290.2014.00055.

Validation of 64Cu-DOTA-rituximab injection preparation under good manufacturing practices: a PET tracer for imaging of B-cell non-Hodgkin lymphoma

Free article

Validation of 64Cu-DOTA-rituximab injection preparation under good manufacturing practices: a PET tracer for imaging of B-cell non-Hodgkin lymphoma

Arutselvan Natarajan et al. Mol Imaging. 2015.
Free article

Abstract

Manufacturing of 64Cu-1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid (DOTA)-rituximab injection under good manufacturing practices (GMP) was validated for imaging of patients with CD20+ B-cell non-Hodgkin lymphoma. Rituximab was purified by size exclusion high performance liquid chromatography (HPLC) and conjugated to DOTA-mono-(N-hydroxysuccinimidyl) ester. 64CuCl2, buffers, reagents, and other raw materials were obtained as high-grade quality. Following a semi-automated synthesis of 64Cu-DOTA-rituximab, a series of quality control tests was performed. The product was further tested in vivo using micro-positron emission tomography/computed tomography (PET/CT) to assess targeting ability towards human CD20 in transgenic mice. Three batches of 64Cu-DOTA-rituximab final product were prepared as per GMP specifications. The radiolabeling yield from these batches was 93.1 ± 5.8%; these provided final product with radiopharmaceutical yield, purity, and specific activity of 59.2 ± 5.1% (0.9 ± 0.1 GBq of 64Cu), > 95% (by HPLC and radio-thin layer chromatography), and 229.4 ± 43.3 GBq/µmol (or 1.5 ± 0.3 MBq/µg), respectively. The doses passed apyrogenicity and human serum stability specifications, were sterile up to 14 days, and retained > 60% immunoreactivity. In vivo micro-PET/CT mouse images at 24 hours postinjection showed that the tracer targeted the intended sites of human CD20 expression. Thus, we have validated the manufacturing of GMP grade 64Cu-DOTA-rituximab for injection in the clinical setting.

PubMed Disclaimer

Publication types

LinkOut - more resources