. 2015 Oct;23(10):3089-93.
doi: 10.1007/s00520-015-2682-0. Epub 2015 Mar 13.

Development and first data of a customized short tracheal cannula based on digital data

Affiliations

Development and first data of a customized short tracheal cannula based on digital data

Rainer Müller et al. Support Care Cancer. 2015 Oct.

Abstract

Purpose: At the moment, there is an inadequate margin fit of commercially available stoma buttons. The aim of the present study was to develop a customized short tracheal cannula based on digital data. Furthermore, the applied material has to be evaluated considering germ colonization and appropriate cleaning procedures.

Methods: Computed tomographies of 53 patients who underwent laryngectomy were surveyed. Based on the digital data, a customized short tracheal cannula was created and manufactured from silicone. The new cannula was incorporated in ten patients and worn for 4 weeks. A clinical examination of an otolaryngologist and subjective assessment of the patients were carried out. Furthermore, microbiological test considering germ colonization was performed.

Results: The customized short tracheal cannula could be incorporated in all patients. The clinical results showed no irritation or mucosal lesions. The subjective individual evaluation by the patients was promising. The proposals for improvement could be considered. The microbiological examination revealed a higher contamination of the silicone compared to the silver cannulas. Both chemical and mechanical decontamination showed sufficient results.

Conclusion: A workflow for development and manufacturing of a customized short tracheal cannula from digital data could be established. The cannula is compatible to standard equipment and routine cleaning procedures. Clinical studies are required to evaluate the potential benefit for patients.

PubMed Disclaimer

Similar articles

Cited by

  • 3D printing for airway disease.
    Alraiyes AH, Avasarala SK, Machuzak MS, Gildea TR. Alraiyes AH, et al. AME Med J. 2019 Feb;4:14. doi: 10.21037/amj.2019.01.05. Epub 2019 Feb 13. AME Med J. 2019. PMID: 31650103 Free PMC article.

References

    1. Laryngorhinootologie. 2009 Feb;88(2):80-3 - PubMed
    1. Dtsch Zahnarztl Z. 1966 Jan 1;21(1):163-7 - PubMed
    1. Acta Otolaryngol. 2006 Dec;126(11):1218-24 - PubMed
    1. Semin Surg Oncol. 2001 Jan-Feb;20(1):66-74 - PubMed
    1. Laryngol Rhinol Otol (Stuttg). 1981 Jul;60(7):359-60 - PubMed

Publication types

LinkOut - more resources