Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2015 Jun;43(6):1380-5.
doi: 10.1177/0363546515574062. Epub 2015 Mar 12.

Biomechanical comparison of 2 anterior cruciate ligament graft preparation techniques for tibial fixation: adjustable-length loop cortical button or interference screw

Affiliations
Comparative Study

Biomechanical comparison of 2 anterior cruciate ligament graft preparation techniques for tibial fixation: adjustable-length loop cortical button or interference screw

Raul Mayr et al. Am J Sports Med. 2015 Jun.

Abstract

Background: Cortical button fixation at the femoral side and interference screws within the tibial bone tunnel are widely used for anterior cruciate ligament graft fixation. Using a bone socket instead of a full tunnel allows cortical button fixation on the tibial side as well. If adjustable-length loop cortical button devices are used for femoral and tibial fixation, the tendon graft has to be secured with sutures in a closed tendon loop. The increased distance of fixation points and potential slippage of the tendon strands at the securing sutures might lead to greater risk of postoperative graft elongation when compared with conventional graft preparation with tibial interference screw fixation.

Hypothesis: Compared with an anterior cruciate ligament graft with tibial adjustable-length loop cortical button fixation, a graft with tibial interference screw fixation will show less graft elongation during cyclic loading and lower ultimate failure loads.

Study design: Controlled laboratory study.

Methods: Grafts with tibial adjustable-length loop cortical button fixation and grafts with tibial interference screw fixation were biomechanically tested in calf tibiae (n = 10 per group). Femoral fixation was equivalent for both groups, using an adjustable-length loop cortical button. Specimens underwent cyclic loading followed by a load-to-failure test.

Results: Grafts with screw fixation showed significantly less initial elongation (cycles 1-5: 1.46 ± 0.26 mm), secondary elongation (cycles 6-1000: 1.87 ± 0.67 mm), and total elongation (cycles 1-1000: 3.33 ± 0.83 mm) in comparison with grafts with button fixation (2.47 ± 0.26, 3.56 ± 0.39, and 6.03 ± 0.61 mm, respectively) (P < .001). While pull-out stiffness was significantly higher for grafts with screw fixation (309.5 ± 33.2 vs 185.6 ± 16.4 N/mm) (P < .001), grafts with button fixation were able to withstand significantly higher ultimate failure loads (908 ± 74 vs 693 ± 119 N) (P < .001).

Conclusion: Grafts with tibial adjustable-length loop cortical button fixation resulted in higher graft elongation during cyclic loading and showed higher ultimate failure loads in comparison with conventional graft preparation with tibial interference screw fixation at time zero.

Clinical relevance: The results of this biomechanical study suggest that grafts with tibial interference screw fixation provide better knee stability at time zero because of reduced graft elongation and greater stiffness in comparison with grafts with tibial adjustable-length loop cortical button fixation.

Keywords: all-inside; anterior cruciate ligament; biomechanics; cortical fixation; interference screw; reconstruction.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources