Integrated electrochemical microsystems for genetic detection of pathogens at the point of care
- PMID: 25785632
- DOI: 10.1021/ar500456w
Integrated electrochemical microsystems for genetic detection of pathogens at the point of care
Abstract
The capacity to achieve rapid, sensitive, specific, quantitative, and multiplexed genetic detection of pathogens via a robust, portable, point-of-care platform could transform many diagnostic applications. And while contemporary technologies have yet to effectively achieve this goal, the advent of microfluidics provides a potentially viable approach to this end by enabling the integration of sophisticated multistep biochemical assays (e.g., sample preparation, genetic amplification, and quantitative detection) in a monolithic, portable device from relatively small biological samples. Integrated electrochemical sensors offer a particularly promising solution to genetic detection because they do not require optical instrumentation and are readily compatible with both integrated circuit and microfluidic technologies. Nevertheless, the development of generalizable microfluidic electrochemical platforms that integrate sample preparation and amplification as well as quantitative and multiplexed detection remains a challenging and unsolved technical problem. Recognizing this unmet need, we have developed a series of microfluidic electrochemical DNA sensors that have progressively evolved to encompass each of these critical functionalities. For DNA detection, our platforms employ label-free, single-step, and sequence-specific electrochemical DNA (E-DNA) sensors, in which an electrode-bound, redox-reporter-modified DNA "probe" generates a current change after undergoing a hybridization-induced conformational change. After successfully integrating E-DNA sensors into a microfluidic chip format, we subsequently incorporated on-chip genetic amplification techniques including polymerase chain reaction (PCR) and loop-mediated isothermal amplification (LAMP) to enable genetic detection at clinically relevant target concentrations. To maximize the potential point-of-care utility of our platforms, we have further integrated sample preparation via immunomagnetic separation, which allowed the detection of influenza virus directly from throat swabs and developed strategies for the multiplexed detection of related bacterial strains from the blood of septic mice. Finally, we developed an alternative electrochemical detection platform based on real-time LAMP, which not is only capable of detecting across a broad dynamic range of target concentrations, but also greatly simplifies quantitative measurement of nucleic acids. These efforts represent considerable progress toward the development of a true sample-in-answer-out platform for genetic detection of pathogens at the point of care. Given the many advantages of these systems, and the growing interest and innovative contributions from researchers in this field, we are optimistic that iterations of these systems will arrive in clinical settings in the foreseeable future.
Similar articles
-
Ultrasensitive electrochemical biomolecular detection using nanostructured microelectrodes.Acc Chem Res. 2014 Aug 19;47(8):2417-25. doi: 10.1021/ar500130m. Epub 2014 Jun 25. Acc Chem Res. 2014. PMID: 24961296
-
Enabling Multiplexed Electrochemical Detection of Biomarkers with High Sensitivity in Complex Biological Samples.Acc Chem Res. 2021 Sep 21;54(18):3529-3539. doi: 10.1021/acs.accounts.1c00382. Epub 2021 Sep 3. Acc Chem Res. 2021. PMID: 34478255
-
Highly-integrated lab-on-chip system for point-of-care multiparameter analysis.Lab Chip. 2012 Feb 7;12(3):464-73. doi: 10.1039/c1lc20693a. Epub 2011 Oct 28. Lab Chip. 2012. PMID: 22038328
-
Helicase-dependent isothermal amplification: a novel tool in the development of molecular-based analytical systems for rapid pathogen detection.Anal Bioanal Chem. 2018 Jan;410(3):679-693. doi: 10.1007/s00216-017-0620-3. Epub 2017 Sep 20. Anal Bioanal Chem. 2018. PMID: 28932883 Free PMC article. Review.
-
Electrochemical real-time nucleic acid amplification: towards point-of-care quantification of pathogens.Trends Biotechnol. 2013 Dec;31(12):704-12. doi: 10.1016/j.tibtech.2013.09.005. Epub 2013 Oct 24. Trends Biotechnol. 2013. PMID: 24209384 Review.
Cited by
-
Printable Electrochemical Biosensors: A Focus on Screen-Printed Electrodes and Their Application.Sensors (Basel). 2016 Oct 21;16(10):1761. doi: 10.3390/s16101761. Sensors (Basel). 2016. PMID: 27775661 Free PMC article. Review.
-
Extended Review Concerning the Integration of Electrochemical Biosensors into Modern IoT and Wearable Devices.Biosensors (Basel). 2024 Apr 25;14(5):214. doi: 10.3390/bios14050214. Biosensors (Basel). 2024. PMID: 38785688 Free PMC article. Review.
-
Passively driven microfluidic device with simple operation in the development of nanolitre droplet assay in nucleic acid detection.Sci Rep. 2021 Oct 25;11(1):21019. doi: 10.1038/s41598-021-00470-9. Sci Rep. 2021. PMID: 34697372 Free PMC article.
-
The Integration of Gold Nanoparticles with Polymerase Chain Reaction for Constructing Colorimetric Sensing Platforms for Detection of Health-Related DNA and Proteins.Biosensors (Basel). 2022 Jun 16;12(6):421. doi: 10.3390/bios12060421. Biosensors (Basel). 2022. PMID: 35735568 Free PMC article.
-
Intelligent salivary biosensors for periodontitis: in vitro simulation of oral oxidative stress conditions.Med Biol Eng Comput. 2024 Aug;62(8):2409-2434. doi: 10.1007/s11517-024-03077-0. Epub 2024 Apr 13. Med Biol Eng Comput. 2024. PMID: 38609577
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources