Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Jan-Mar;4(1):28-33.
doi: 10.4103/2303-9027.151320.

Comparison of endoscopic ultrasound guided 22-gauge core needle with standard 25-gauge fine-needle aspiration for diagnosing solid pancreatic lesions

Affiliations

Comparison of endoscopic ultrasound guided 22-gauge core needle with standard 25-gauge fine-needle aspiration for diagnosing solid pancreatic lesions

Manuel Berzosa et al. Endosc Ultrasound. 2015 Jan-Mar.

Abstract

Background and objectives: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is the standard modality for diagnosing pancreatic masses. We compared the diagnostic yield of a new EUS-guided 22-gauge core needle biopsy to a standard 25-gauge FNA in sampling the same pancreatic lesions during the same EUS.

Patients and methods: The main outcomes of the study were the sample adequacy of each method to provide a final pathological diagnosis, and the concordance in diagnosis between core and FNA specimens. The secondary outcomes were the sensitivity and specificity of the findings for each needle and the incremental yield of using both needles compared with using each needle alone.

Results: A total of 56 patients with 61 solid pancreatic lesions were evaluated. The mean number of passes with FNA was 3.5 (ranges 1-8) and with core biopsy needle was 1.7 (ranges 1-5). The proportions of adequate samples were 50/61 (81.9%) for FNA and 45/61 (73.8%) for core biopsy (P = 0.37). The diagnostic yield was 46/61 (75.4%), 42/61 (68.9%) and 47/61 (77.1%) for FNA, core, and both, respectively. There was a substantial agreement of 87.5% (κ = 0.77; P < 0.001) in the findings of core and FNA specimens. The sensitivity for the diagnosis of malignancy for FNA and core biopsy were 68.1% and 59.6%, respectively (P = no significant [NS]). The specificity was 100% for both methods. The incremental increase in sensitivity and specificity by combining both methods are 1.5% and 0%, respectively.

Conclusion: There are NS differences in the diagnostic yield between EUS-guided 22-gauge core biopsy and standard 25-gauge FNA for diagnosing pancreatic lesions, but core biopsy required fewer numbers of passes. There was NS incremental diagnostic yield when using both needles during the same procedure.

Keywords: 22-gauge; 25-gauge; core; endoscopic ultrasound; fine-needle aspiration; pancreas.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest: None declared.

References

    1. Eloubeidi MA, Chen VK, Eltoum IA, et al. Endoscopic ultrasound-guided fine needle aspiration biopsy of patients with suspected pancreatic cancer: Diagnostic accuracy and acute and 30-day complications. Am J Gastroenterol. 2003;98:2663–8. - PubMed
    1. Afify AM, al-Khafaji BM, Kim B, et al. Endoscopic ultrasound-guided fine needle aspiration of the pancreas. Diagnostic utility and accuracy. Acta Cytol. 2003;47:341–8. - PubMed
    1. Iglesias-Garcia J, Dominguez-Munoz JE, Abdulkader I, et al. Influence of on-site cytopathology evaluation on the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid pancreatic masses. Am J Gastroenterol. 2011;106:1705–10. - PubMed
    1. Varadarajulu S, Fraig M, Schmulewitz N, et al. Comparison of EUS-guided 19-gauge trucut needle biopsy with EUS-guided fine-needle aspiration. Endoscopy. 2004;36:397–401. - PubMed
    1. Levy MJ. Endoscopic ultrasound-guided trucut biopsy of the pancreas: Prospects and problems. Pancreatology. 2007;7:163–6. - PubMed