CT radiation dose and iterative reconstruction techniques
- PMID: 25794087
- DOI: 10.2214/AJR.14.13241
CT radiation dose and iterative reconstruction techniques
Abstract
1. CT radiation dose optimization is one of the major concerns for the scientific community. 2. CT image quality is dependent on the selected image reconstruction algorithm. 3. Iterative reconstruction algorithms have reemerged with the potential of radiation dose optimization by lowering image noise. 4. Tube current is the most common parameter used to reduce radiation dose along with iterative reconstruction. 5. Tube potential (kV) is also used for dose optimization with iterative reconstruction in CT angiography protocols and small patients.
Keywords: CT image quality; CT radiation dose; iterative reconstruction techniques; optimization.
Similar articles
-
Iterative Reconstruction Techniques in Abdominopelvic CT: Technical Concepts and Clinical Implementation.AJR Am J Roentgenol. 2015 Jul;205(1):W19-31. doi: 10.2214/AJR.14.13402. AJR Am J Roentgenol. 2015. PMID: 26102414 Review.
-
Introduction of an effective method for the optimization of CT protocols using iterative reconstruction algorithms: comparison with patient data.AJR Am J Roentgenol. 2014 Oct;203(4):W434-9. doi: 10.2214/AJR.13.11973. AJR Am J Roentgenol. 2014. PMID: 25247973
-
Individualized kV selection and tube current reduction in excretory phase computed tomography urography: potential for radiation dose reduction and the contribution of iterative reconstruction to image quality.J Comput Assist Tomogr. 2013 Jul-Aug;37(4):551-9. doi: 10.1097/RCT.0b013e31828f871f. J Comput Assist Tomogr. 2013. PMID: 23863531
-
Reducing CT radiation dose with iterative reconstruction algorithms: the influence of scan and reconstruction parameters on image quality and CTDIvol.Eur J Radiol. 2014 Sep;83(9):1645-54. doi: 10.1016/j.ejrad.2014.05.033. Epub 2014 Jun 5. Eur J Radiol. 2014. PMID: 25037931
-
A new era in computed tomographic dose optimization: the impact of iterative reconstruction on image quality and radiation dose.J Comput Assist Tomogr. 2013 Nov-Dec;37(6):924-31. doi: 10.1097/RCT.0b013e318282d95a. J Comput Assist Tomogr. 2013. PMID: 24270114 Review.
Cited by
-
Effects of tube voltage, radiation dose and adaptive statistical iterative reconstruction strength level on the detection and characterization of pulmonary nodules in ultra-low-dose chest CT.Cancer Imaging. 2024 Sep 15;24(1):123. doi: 10.1186/s40644-024-00770-z. Cancer Imaging. 2024. PMID: 39278933 Free PMC article.
-
Deep learning CT reconstruction improves liver metastases detection.Insights Imaging. 2024 Jul 6;15(1):167. doi: 10.1186/s13244-024-01753-1. Insights Imaging. 2024. PMID: 38971933 Free PMC article.
-
Noise reduction profile: A new method for evaluation of noise reduction techniques in CT.Med Phys. 2022 Jan;49(1):186-200. doi: 10.1002/mp.15382. Epub 2021 Dec 15. Med Phys. 2022. PMID: 34837717 Free PMC article.
-
An untapped potential for imaging of peripheral osteomyelitis in paediatrics using [18F]FDG PET/CT -the inference from a juvenile porcine model.EJNMMI Res. 2019 Mar 22;9(1):29. doi: 10.1186/s13550-019-0498-5. EJNMMI Res. 2019. PMID: 30903403 Free PMC article.
-
Low-dose ultra-high-pitch computed tomography coronary angiography: identifying the optimum combination of iteration strength and radiation dose reduction strategies to achieve true submillisievert scans.Diagn Interv Radiol. 2023 Mar 29;29(2):268-275. doi: 10.4274/dir.2021.0849. Epub 2023 Mar 20. Diagn Interv Radiol. 2023. PMID: 36987879 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical