Effect of thermocycling with or without 1 year of water storage on retentive strengths of luting cements for zirconia crowns
- PMID: 25794911
- DOI: 10.1016/j.prosdent.2014.12.001
Effect of thermocycling with or without 1 year of water storage on retentive strengths of luting cements for zirconia crowns
Abstract
Statement of problem: Bond stability between zirconia crowns and luting cement and between cement and dentin is a main concern; however, only limited evidence is available as to its longevity.
Purpose: The purpose of this in vitro study was to measure the retentive strengths of 7 self-adhesive cements (RelyX Unicem Aplicap, RelyX Unicem Clicker, RelyX Unicem 2 Automix, iCEM, Maxcem Elite, Bifix SE, SpeedCem), 2 adhesive cements with self-etch primers (Panavia 21, SEcure), 1 glass ionomer cement (Ketac Cem), 1 resin-modified glass ionomer cement (Meron Plus), and 1 zinc phosphate cement for luting zirconia crowns (LAVA) to extracted teeth after thermocycling with or without 1 year of water storage.
Material and methods: Two-hundred-forty extracted human molars (2 treatments; n=10 per cement) were prepared in a standardized manner. All cements were used according to the manufacturers' recommendations. The intaglios of the crowns were treated with airborne-particle abrasion. After thermocycling (×5000, 5°C/55°C) with or without 1 year of water storage, the cemented ceramic crowns were removed by using a Zwick universal testing device. Statistical analyses were done with the Wilcoxon rank sum and the 2-independent-samples Kolmogorov-Smirnov test.
Results: Median retentive strengths [MPa] for specimens thermocycled only/thermocycled with 1 year of water storage were as follows: Panavia 21: 1.7/2.5, SEcure: 3.0/3.0, RelyX Unicem Aplicap: 3.1/3.4, RelyX Unicem Clicker: 4.1/4.2, RelyX Unicem 2 Automix: 3.8/3.1, iCEM: 2.3/2.7, Maxcem Elite: 3.0/3.2, Bifix SE: 1.7/1.7, SpeedCem: 1.3/1.6, Meron Plus: 3.1/2.7, Ketac Cem: 1.4/1.4, and zinc phosphate cement: 1.1/1.6. Statistically significant differences were found only among specimens thermocycled only or thermocycled with 1-year water storage (P<.001).
Conclusions: Significant differences in retentive strengths were observed among cements after thermocycling only or thermocycling with 1 year of water storage, but not for the effect of the additional 1 year of water storage.
Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Similar articles
-
In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents.J Prosthet Dent. 2005 Jun;93(6):551-8. doi: 10.1016/j.prosdent.2005.04.011. J Prosthet Dent. 2005. PMID: 15942616
-
Influence of internal-gap width and cement type on the retentive force of zirconia copings in pullout testing.J Dent. 2012 Oct;40(10):866-72. doi: 10.1016/j.jdent.2012.07.007. Epub 2012 Jul 20. J Dent. 2012. PMID: 22819954
-
Influence of different luting concepts on long term retentive strength of zirconia crowns.Am J Dent. 2009 Apr;22(2):122-8. Am J Dent. 2009. PMID: 19626977
-
Crown pull-off test (crown retention test) to evaluate the bonding effectiveness of luting agents.Dent Mater. 2010 Mar;26(3):193-206. doi: 10.1016/j.dental.2009.10.004. Epub 2009 Nov 20. Dent Mater. 2010. PMID: 19931901
-
Trends in indirect dentistry: 3. Luting materials.Dent Update. 2005 Jun;32(5):251-4, 257-8, 260. doi: 10.12968/denu.2005.32.5.251. Dent Update. 2005. PMID: 15977720 Review.
Cited by
-
Shear Bond Strength of Al₂O₃ Sandblasted Y-TZP Ceramic to the Orthodontic Metal Bracket.Materials (Basel). 2017 Feb 9;10(2):148. doi: 10.3390/ma10020148. Materials (Basel). 2017. PMID: 28772508 Free PMC article.
-
Influence of Hydrofluoric and Nitric Acid Pre-Treatment and Type of Adhesive Cement on Retention of Zirconia Crowns.Materials (Basel). 2021 Feb 18;14(4):960. doi: 10.3390/ma14040960. Materials (Basel). 2021. PMID: 33670574 Free PMC article.
-
Shear bond strength of different luting agents to polyether ether ketone.Dent Res J (Isfahan). 2022 Jun 1;19:45. eCollection 2022. Dent Res J (Isfahan). 2022. PMID: 35915713 Free PMC article.
-
Evaluation of the Color Stability of Three Resin-Ceramic Materials Using a Spectrophotometer and a Digital Photography Software.Contemp Clin Dent. 2024 Jan-Mar;15(1):44-50. doi: 10.4103/ccd.ccd_656_18. Epub 2024 Mar 23. Contemp Clin Dent. 2024. PMID: 38707666 Free PMC article.
-
Fracture strength of veneered translucent zirconium dioxide crowns with different porcelain thicknesses.Acta Biomater Odontol Scand. 2017 Nov 14;3(1):74-83. doi: 10.1080/23337931.2017.1403288. eCollection 2017. Acta Biomater Odontol Scand. 2017. PMID: 29242815 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials