Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Jun;113(6):609-15.
doi: 10.1016/j.prosdent.2014.12.001. Epub 2015 Mar 18.

Effect of thermocycling with or without 1 year of water storage on retentive strengths of luting cements for zirconia crowns

Affiliations

Effect of thermocycling with or without 1 year of water storage on retentive strengths of luting cements for zirconia crowns

Vicky Ehlers et al. J Prosthet Dent. 2015 Jun.

Abstract

Statement of problem: Bond stability between zirconia crowns and luting cement and between cement and dentin is a main concern; however, only limited evidence is available as to its longevity.

Purpose: The purpose of this in vitro study was to measure the retentive strengths of 7 self-adhesive cements (RelyX Unicem Aplicap, RelyX Unicem Clicker, RelyX Unicem 2 Automix, iCEM, Maxcem Elite, Bifix SE, SpeedCem), 2 adhesive cements with self-etch primers (Panavia 21, SEcure), 1 glass ionomer cement (Ketac Cem), 1 resin-modified glass ionomer cement (Meron Plus), and 1 zinc phosphate cement for luting zirconia crowns (LAVA) to extracted teeth after thermocycling with or without 1 year of water storage.

Material and methods: Two-hundred-forty extracted human molars (2 treatments; n=10 per cement) were prepared in a standardized manner. All cements were used according to the manufacturers' recommendations. The intaglios of the crowns were treated with airborne-particle abrasion. After thermocycling (×5000, 5°C/55°C) with or without 1 year of water storage, the cemented ceramic crowns were removed by using a Zwick universal testing device. Statistical analyses were done with the Wilcoxon rank sum and the 2-independent-samples Kolmogorov-Smirnov test.

Results: Median retentive strengths [MPa] for specimens thermocycled only/thermocycled with 1 year of water storage were as follows: Panavia 21: 1.7/2.5, SEcure: 3.0/3.0, RelyX Unicem Aplicap: 3.1/3.4, RelyX Unicem Clicker: 4.1/4.2, RelyX Unicem 2 Automix: 3.8/3.1, iCEM: 2.3/2.7, Maxcem Elite: 3.0/3.2, Bifix SE: 1.7/1.7, SpeedCem: 1.3/1.6, Meron Plus: 3.1/2.7, Ketac Cem: 1.4/1.4, and zinc phosphate cement: 1.1/1.6. Statistically significant differences were found only among specimens thermocycled only or thermocycled with 1-year water storage (P<.001).

Conclusions: Significant differences in retentive strengths were observed among cements after thermocycling only or thermocycling with 1 year of water storage, but not for the effect of the additional 1 year of water storage.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms